A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Field evaluation of a locally produced rapid diagnostic test for early detection of cholera in Bangladesh. | LitMetric

Background: Cholera remains a substantial health burden in Asia and Africa particularly in resource poor settings. The standard procedures to identify the etiological organism V. cholerae are isolation from microbiological culture from stool as well as Polymerase Chain Reaction (PCR). Both the processes are highly lab oriented, labor extensive, time consuming, and expensive. In an effort to control for outbreaks and epidemics; an effective, convenient, quick and relatively less expensive detection method is imperative, without compromising the sensitivity and specificity that exists at present. The objective of this component of the study was to evaluate the effectiveness of a locally produced rapid diagnostic test (RDT) for cholera diagnosis.

Methods: In Bangladesh, nationwide cholera surveillance is ongoing in 22 hospitals covering all 8 divisions of the country since June, 2016. In the surveillance, stool samples have been collected from patients presenting to hospitals with acute watery diarrhea. Crystal VCTM (Span diagnostics, India) and Cholkit (locally produced RDT) have been used to detect V. cholerae from stool samples. Samples have also been sent to the main laboratory at icddr,b where the culture based isolation is routinely performed. All the tests were carried out for both direct and enriched stool samples. RDT sensitivity and specificity were calculated using stool culture as the gold standard.

Results: A total of 7720 samples were tested. Among these, 5865 samples were solely tested with Crystal VC and 1355 samples with Cholkit whereas 381 samples were tested with both the RDTs. In comparison with culture, direct testing with Crystal VC showed a sensitivity of 72% (95% CI: 50.6% to 87.9%) and specificity of 86.8% (95% CI: 82.8% to 90.1%). After enrichment the sensitivity and specificity was 68% (95% CI: 46.5% to 85.1%) and 97.5% (95% CI: 95.3% to 98.8%) respectively. The direct Cholkit test showed sensitivity of 76% (95% CI: 54.9% to 90.6%) and specificity of 90.2% (95% CI: 86.6% to 93.1%).

Conclusion: This evaluation has demonstrated that the sensitivity and specificity of Cholkit is similar to the commercially available test, Crystal VC when used in field settings for detecting V. cholerae from stool specimens. The findings from this study suggest that the Cholkit could be a possible alternative for cholera endemic regions where V. cholerae O1 is the major causative organism causing cholera.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6372204PMC
http://dx.doi.org/10.1371/journal.pntd.0007124DOI Listing

Publication Analysis

Top Keywords

sensitivity specificity
16
locally produced
12
stool samples
12
produced rapid
8
rapid diagnostic
8
diagnostic test
8
samples
8
cholerae stool
8
samples tested
8
cholera
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!