Objective: To evaluate key corneal tomography parameters for screening refractive surgery patients in Pakistani population.
Study Design: Cross-sectional, observation study.
Place And Duration Of Study: Armed Forces Institute of Ophthalmology AFIO, National University of Medical Sciences, Rawalpindi, Pakistan, from August 2013 to December 2016.
Methodology: Myopic patients were evaluated by two separate observers on Allegro OculyzerII (Wavelight) for normal ocular examination. A total of 20 tomographic parameters, used for pre-refractive surgical evaluation, were included. Normality of data was evaluated using Kolmogorov-Smirnov test. Results for outliers were displayed as 2.5%, 5%, 95% and 97.5% percentiles.
Results: The sample of 451 patients (895 eyes), comprised of 61% (n=277) females and 39% (n=174) males (39%). The mean age was 26 +6.4 years (range of 18-62 years, M=F). Normal mean anterior segment values included; flat simulated keratometry (K1) 42.9 ±1.44 diopters (D), steep K2 43.9 ±1.52 D, K mean 43.4 ±1.43 D, K maximum 44.6 ±1.56 D, astigmatism -0.96 ±0.97 D, anterior chamber depth (ACD) 3.19 ±0.28 mm, front elevation at the thinnest point 4.11 ±2.44 um, and that at the back was 7.56 ±4.52 um progression index (PI) maximum 1.14 ±0.17, Ambrosio relational thickness maximum (ART max) 487.5 ±89.0 and pachymetry at thinnest point 542.2 ± 31.1 um.
Conclusion: The study demonstrates key corneal tomography parameters, which can be useful for screening refractive surgery patients in Pakistani population.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.29271/jcpsp.2019.02.128 | DOI Listing |
Pain Rep
February 2025
Department of Neurology, University Hospital Würzburg, Würzburg, Germany.
About 50% of women with fibromyalgia syndrome have reduced skin innervation. This finding is consistent in patient cohorts from different regions of the world. Small fiber function may also be affected, as shown by various studies using different methods, such as quantitative sensory testing or special small fiber neurophysiology such as C-fiber microneurography.
View Article and Find Full Text PDFCureus
November 2024
Ophthalmology, International University of Health and Welfare, Chiba, JPN.
Keratoconus is a condition that causes progressive thinning and anterior protrusion of the cornea. Because of its irregular astigmatism, mild to moderate keratoconus is corrected with hard contact lenses (HCLs), but blepharoptosis due to the long-term wearing of HCLs is often a problem. In this study, we investigated blepharoptosis in HCL wearers with keratoconus.
View Article and Find Full Text PDFIndian J Ophthalmol
January 2025
Department of Ophthalmology, Université Paris Cité, Cochin Hospital, Assistance Publique-Hôpitaux de Paris, Paris, France.
Purpose: This study aims to evaluate the efficacy of various tomographic indices, both established and novel, in predicting endothelial decompensation leading to either spontaneous corneal transplantation or transplantation following cataract surgery in patients with Fuchs endothelial corneal dystrophy (FECD).
Methods: In this cross-sectional, retrospective study, we reviewed the files of 93 eyes from 54 FECD patients undergoing regular follow-up. We recorded clinical metrics such as morning visual disturbance (MVD) and corrected distance visual acuity.
Front Vet Sci
November 2024
Department of Pathology, Microbiology and Immunology, School of Veterinary Medicine, University of California, Davis, Davis, CA, United States.
Sjogren's disease, well-described in people, is rarely identified in veterinary species. In people, Sjogren's disease is one of the most common systemic autoimmune disorders with an incidence of 0.5% in the female population.
View Article and Find Full Text PDFBiomed Phys Eng Express
December 2024
ATISP laboratory, ENET'com, University of Sfax, Tunisia.
In this paper, an automated feature selection (FS) method is presented to optimize machine learning (ML) models' performances, enhancing early keratoconus screening. A total of 448 parameters were analyzed from a dataset comprising 3162 observations sourced from the swept source optical coherence tomography imaging system developed by the Chinese Academy of Sciences Institute of Automation (SS-1000 CASIA OCT) and electronic health records (EHR). To identify the most relevant features, the analysis of variance (ANOVA) method was used in this study.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!