Evaluation of common suturing techniques to secure implantable cardiac electronic device leads: Which strategy best reduces the lead dislodgement risk?

Can J Surg

From the Libin Cardiovascular Institute of Alberta, Department of Cardiac Sciences, University of Calgary, Calgary, Alta. (Rezazadeh, Rizkallah); and the Division of Electrophysiology, Saint John Regional Hospital, Saint John, NB (Wang).

Published: February 2019

Implantable cardiac electronic device lead dislodgment is a relatively common complication and carries significant comorbidities. A potential cause of lead dislodgement includes inadequate anchoring along the lead suture sleeve at the venous insertion site. We assessed which of the 3 commonly applied knot-tying techniques results in the most effective anchoring of a pacing lead along its suture sleeve, which could be associated with minimized lead motion postimplant. Following controlled traction force measurements, the anchor knot technique offered the greatest amount of lead stability when compared with the simple knot and the looping knot techniques.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6351253PMC
http://dx.doi.org/10.1503/cjs.002418DOI Listing

Publication Analysis

Top Keywords

implantable cardiac
8
cardiac electronic
8
electronic device
8
lead dislodgement
8
lead suture
8
suture sleeve
8
lead
7
evaluation common
4
common suturing
4
suturing techniques
4

Similar Publications

Infectious myocarditis (IM) and infective endocarditis (IE), sometimes associated with infection of the surrounding mediastinal tissue or embolic complications caused by residual implantable cardioverter defibrillator (ICD) lead material embedded in the ventricle, present a significant challenge for cardiac surgeons due to the difficulty of precisely locating the old intracardiac pacing lead remnants because of the heart's continuous movement. We present the case of successful two-stage elective sternotomy extraction of two residual defibrillator leads, one trapped in the left innominate vein, easily removed after veinotomy without cardiopulmonary bypass (CPB), and the other embedded intramyocardially in the inferior wall of the right ventricle, successfully removed under CPB after fluoroscopic guidance. The patient was discharged four weeks post-operation without complications.

View Article and Find Full Text PDF

Background: Risk stratification for sudden cardiac death (SCD) in patients with nonischemic cardiomyopathy (NICM) remains challenging.

Objectives: This study aimed to investigate the impact of epicardial adipose tissue (EAT) on SCD in NICM patients.

Methods: Our study cohort included 173 consecutive patients (age 53 ± 14 years, 73% men) scheduled for primary prevention implantable cardioverter-defibrillators (ICDs) implantation who underwent preimplant cardiovascular magnetic resonance.

View Article and Find Full Text PDF

Current guidelines recommend cardioverter-defibrillator (ICD) programming, including faster detection rates, longer detection durations, and strict discrimination for supraventricular tachycardia (SVT) to prevent unnecessary ICD treatment. This delayed-style ICD programming could lead to a rise in the possibility of VF undersensing. To avoid this risk, an innovative algorithm known as VF Therapy Assurance (VFTA; Abbott, Sylmar, CA) has been developed.

View Article and Find Full Text PDF

Background: Removal of cardiac implantable electronic devices (CIEDs) is strongly recommended for CIED-related infections, and leadless pacemakers (LPs) are increasingly used for reimplantation. However, the optimal timing and safety of LP implantation after CIED removal for infection remains unclear.This systematic review and meta-analysis aimed to assess complication rates (all-cause mortality and reinfection) when LP implantation was performed simultaneously with or after CIED removal.

View Article and Find Full Text PDF

Background: The most effective way to treat patients following a first ICD therapy is unclear. We hypothesised that following first ICD therapy, combining different treatment strategies would be associated with a reduction in the risk of subsequent therapy compared to single strategies alone.

Methods: Data was collected from consecutive patients undergoing ICD implantation at King's College Hospital between January 2009 and December 2019.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!