Assessing coronary artery calcium (CAC) is a valuable tool for individualizing cardiac risk assessment. In CAC scanning, this technical report assesses the use of a true model-based iterative reconstruction algorithm using forward projected model-based iterative reconstruction ("FIRST") and assess whether FIRST allows for reduced radiation dose CAC scanning on 320-detector row computed tomography (320-CT). Here, 100 consecutive patients prospectively underwent reduced and standard dose scans. For the patients (59 ± 9 years, 61% male) stratified by Agatston categories 0, 1-10, 11-100, 101-400,> 400, agreement between reduced dose with FIRST versus standard dose with FBP was excellent at 81% (95% CI: 73-88%) with kappa 0.74 (95% CI: 0.64-0.85). Median radiation exposure was 75% lower for reduced (0.35 mSv) versus standard dose (1.37 mSv) scans. In conclusion, agreement was excellent for reduced dose with FIRST and standard dose with FBP in 320-detector row CT CAC imaging in well-established categories of cardiovascular risk. These methods make it possible to reduce radiation exposure by 75%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2018.12.010DOI Listing

Publication Analysis

Top Keywords

standard dose
16
iterative reconstruction
12
reduced radiation
8
dose
8
radiation dose
8
coronary artery
8
artery calcium
8
cac scanning
8
model-based iterative
8
320-detector row
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!