We describe here a magnetic bead-based multiplex (pentaplex) immunoassay (MIA) platform developed as an alternative to enzyme-linked immunosorbent assays (ELISA) used in immunogenicity testing of DTaP/TdaP vaccine in animals. MIA simultaneously measures the concentration of serum (IgG) antibodies against B. Pertussis antigens; pertussis toxin, filamentous hemagglutinin (FHA), pertactin (PRN) and tetanus (T) and diphtheria (D) toxoid in the Tdap vaccine immunized animals. Assay validation experiments were done using a panel of serum samples. The results are expressed in IU/ml using WHO reference mice serum. The standard curve was linear with 4PL logistic fit over an eight 2-fold dilution range with LOQ of 0.003, 0.022, 0.005 IU/ml for PT, FHA and PRN and 0.016 U/ml for T and D antigens indicating sensitivity. No interference was observed in monoplex versus multiplex measurements. Specificity was demonstrated by ≥90% homologous and ≤15% heterologous inhibition for all the antigens. The assay was reproducible, with a mean coefficient of variation (CV) of ≤10% for intra-assay duplicates and ≤25% for interassays using different lots of beads and analyst. Accuracy was demonstrated wherein the ratio of observed vs. assigned unitages were within 80-120%. The study suggests that the Pentaplex (MIA) platform meets all the criteria for the serological assay combination vaccines with additional advantages of high throughput, reduced sample volumes, faster analysis with reduced manpower in contrast to conventional monoplex ELISA.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ymeth.2019.01.015 | DOI Listing |
J Immunol Methods
April 2022
PharmAbs, KU Leuven, Leuven, Belgium; Clinical and Diagnostic Immunology, KU Leuven, Leuven, Belgium; Laboratory Medicine, University Hospitals Leuven, Leuven, Belgium. Electronic address:
A multiplex assay for the quantitation of immunoglobulin G (IgG) serum antibodies directed against Clostridium tetani toxin (TT), Corynebacterium diphtheriae toxoid (DTxd), and the Bordetella pertussis antigens pertussis toxin (PT), filamentous hemagglutinin (FHA) and pertactin (Prn) was developed on an Evalution® platform to enhance the evaluation of the specific antibody response towards protein antigens in suspected humoral immunodeficiencies. Evalution® is a microfluidic and microparticle-based platform with the possibility to analyse single samples and to perform real-time kinetic measurements of antibody binding. All individual antigens were covalently linked to the carboxylated microparticles after which samples and fluorescently labelled detection antibodies were flowed over the microparticles in the microfluidic channels of the assay cartridges of the system.
View Article and Find Full Text PDFGroup B (GBS) infections constitute a major cause of invasive disease during the first three months of life and an unmet medical need that could be addressed by maternal vaccination. The GBS capsular polysaccharides (CPSs) have shown promise as vaccine targets in clinical studies. A highly specific serological assay to quantify maternal and neonatal anti-CPS antibody levels will be instrumental for GBS vaccine licensure.
View Article and Find Full Text PDFmSphere
April 2019
Center of Infectious Disease Control, National Institute of Public Health and the Environment (RIVM), Bilthoven, the Netherlands
Human respiratory syncytial virus (RSV) is a major cause of severe respiratory disease in (premature) newborns and causes respiratory illness in the elderly. Different monoclonal antibody (MAb) and vaccine candidates are in development worldwide and will hopefully become available within the near future. To implement such RSV vaccines, adequate decisions about immunization schedules and the different target group(s) need to be made, for which the assessment of antibody levels against RSV is essential.
View Article and Find Full Text PDFMethods
April 2019
Serum Institute of India Pvt Ltd., 212/2, Hadapsar, Pune, Maharashtra 411028, India.
We describe here a magnetic bead-based multiplex (pentaplex) immunoassay (MIA) platform developed as an alternative to enzyme-linked immunosorbent assays (ELISA) used in immunogenicity testing of DTaP/TdaP vaccine in animals. MIA simultaneously measures the concentration of serum (IgG) antibodies against B. Pertussis antigens; pertussis toxin, filamentous hemagglutinin (FHA), pertactin (PRN) and tetanus (T) and diphtheria (D) toxoid in the Tdap vaccine immunized animals.
View Article and Find Full Text PDFAsian Pac J Cancer Prev
January 2017
School of Surgery, University of Western Australia, Perth, Australia E-mail : barry.
Background: Lynch Syndrome (LS) is a familial cancer condition caused by germline mutations in DNA mismatch repair genes. Individuals with LS have a greatly increased risk of developing colorectal cancer (CRC) and it is therefore important to identify mutation carriers so they can undergo regular surveillance. Tumor DNA from LS patients characteristically shows microsatellite instability (MSI).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!