A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The safety of renal denervation as assessed by optical coherence tomography: pre- and post-procedure comparison with multi-electrode ablation catheter in animal experiment. | LitMetric

Objective: To prove the effectiveness and safety of multi-electrode ablation catheter in renal denervation (RDN) by optical coherence tomography (OCT).

Methods: Sixteen renal arteries were enrolled from 8 pigs. Angiography and OCT were performed to analyze the morphological changes before RDN and at 1-month follow-up. Blood pressure and creatinine were measured to prove the effectiveness and safety of the catheter.

Results: One renal artery was excluded because of the small diameter. Fifteen renal arteries successfully underwent renal denervation and OCT. Mean blood pressure was significantly reduced at 1 month after RDN (122.40 ± 3.54 mmHg vs. 106.50 ± 2.06 mmHg, n = 8, P < .001). Creatinine follow-up after 1 month showed no significant change (45.37 ± 7.44 vs. 65.87 ± 49.20 μmol/L, n = 8, P = 0.275). The minimal lumen diameter showed that the renal artery immediately narrowed after the procedure (7.17 ± 0.60 mm vs. 5.93 ± 0.97 mm, n = 15, P < .001). Vasospasm, vascular wall edemas, and thrombus formations all showed significant changes after the procedure except renal artery dissection (0% vs. 21.4%, P = 0.067) under the OCT. Adverse event as renal artery occluded showed no significant difference (0% vs. 6.7%, P > .05). OCT results showed no significant difference in vasospasm, dissections, wall edemas, and thrombus formations (P > .05) at 1 month after the procedure.

Conclusion: This multi-electrode ablation catheter could cause minor injury to renal artery instantly after RDN, but it is found to be safe in the animal model at 1-month follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hjc.2019.01.009DOI Listing

Publication Analysis

Top Keywords

renal denervation
12
multi-electrode ablation
12
ablation catheter
12
optical coherence
8
coherence tomography
8
prove effectiveness
8
effectiveness safety
8
renal arteries
8
1-month follow-up
8
blood pressure
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!