A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3106
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the effects of gas volume and composition on accuracy of volume measurement by two flow sensors and delivery by a piston-driven large-animal ventilator. | LitMetric

OBJECTIVE To evaluate the effects of 4 gas compositions at various volumes (simulated tidal volumes [Vs]) on accuracy of measurements obtained with 2 types of flow sensors and accuracy of gas volume delivery by a piston-driven ventilator. SAMPLE 4 gas mixtures (medical air [21% O:79% N], > 95% O, O-enriched air [30% O:70% N], and heliox [30% O:70% He]). PROCEDURES For each gas mixture, reference Vs of 1 to 8 L were delivered into an anesthetic breathing circuit via calibration syringe; measurements recorded by a Pitot tube-based flow sensor (PTFS) connected to a multiparameter host anesthesia monitor and by a thermal mass flow and volume meter (TMFVM) were compared with the reference values. Following leak and compliance testing, the ventilator was preset to deliver each gas at Vs of 1 to 8 L into the calibration syringe. Effects of gas volume and composition on accuracy of V measurement and delivery were assessed by ANOVA. Agreements between delivered and flow sensor-measured V and preset versus ventilator-delivered V were determined by Bland-Altman analysis. RESULTS Flow sensor measurements were accurate and not influenced by gas composition. Mean measurement error ranges for the PTFS and TMFVM were -4.99% to 4.21% and -4.50% to 0.17%, respectively. There were no significant differences between ventilator-delivered and reference Vs regardless of gas volume or composition. Bland-Altman analysis yielded biases of -0.046 L, -0.007 L, -0.002 L, and 0.031 L for medical air, > 95% O, O-enriched air, and heliox, respectively. CONCLUSIONS AND CLINICAL RELEVANCE The PTFS and the TMFVM measured Vs and the piston-driven ventilator delivered Vs with error rates of < 5% for all gas compositions and volumes tested.

Download full-text PDF

Source
http://dx.doi.org/10.2460/ajvr.80.2.135DOI Listing

Publication Analysis

Top Keywords

gas volume
16
effects gas
12
volume composition
12
gas
10
composition accuracy
8
flow sensors
8
delivery piston-driven
8
gas compositions
8
compositions volumes
8
piston-driven ventilator
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!