A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Open-tubular capillary electrochromatography for the simultaneous determination of cadmium and copper in plants. | LitMetric

We discuss the separation and determination of cadmium and copper in plant samples such as Triticum durum (wheat) and Helianthus annuus (sunflower) using open tubular capillary electrochromatography with indirect detection. Before performing the analysis, the samples were digested by microwave-assisted methods using HNO . Regarding the electrophoretic system, several experimental parameters were previously evaluated such as the capillary surface, mobile phase composition, buffer, pH, and voltage applied. The baseline resolution of the studied metals was obtained within 8 min by using a capillary immobilized with carboxylic multi-walled carbon nanotubes and a background electrolyte composed of 6 mM imidazole, pH 4.0. The applied voltage and the temperature were set at 20 kV and 25°C, respectively. Precision, detection, and quantification limits, along with linearity were investigated. The limits of detection and quantification were 2.20 and 7.40 μg/kg, for Cu ⁺ and 0.05 and 0.20 μg/kg in the case of Cd ⁺. A good linearity was achieved over a concentration working range of 7.5-100 and 0.2-25 μg/kg for Cu ⁺ and Cd ⁺ accordingly. Recovery data for validation studies were found in a range of 98.2-101.5% for both analytes.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.201800853DOI Listing

Publication Analysis

Top Keywords

capillary electrochromatography
8
determination cadmium
8
cadmium copper
8
detection quantification
8
μg/kg ⁺
8
open-tubular capillary
4
electrochromatography simultaneous
4
simultaneous determination
4
copper plants
4
plants discuss
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!