Background: Medical claim data offer the possibility to improve patient care and mitigate liability. Although published analyses exist in cardiology, no information is available for transesophageal echocardiography (TEE). In this study, the authors reviewed medical claims involving TEE to identify potential risk management concerns so that these lessons could be used to improve the safety and quality of transesophageal echocardiographic practice.

Methods: The authors reviewed anonymized clinical and claims data from all closed claims from 2008 to 2013 for a single national physician liability insurer.

Results: There were no claims involving transthoracic echocardiography and eight involving TEE. Three claims involved esophageal perforation, a known risk of TEE. Two claims involved quadriplegia allegedly due to neck manipulation in the setting of a cervical spinal abscess that should have been suspected. Three claims involved the cardiologist's failure to diagnose endocarditis, with allegations that the cardiologist did not perform TEE in an appropriate time frame to avoid major morbidity and mortality from endocarditis.

Conclusions: Liability claims associated with TEE involve failure to order and perform TEE in an appropriate clinical scenario and in a timely manner; failure to properly document medical decision making; failure to inform patients regarding risks of TEE; failure to properly monitor the patient before, during, and after TEE; and technical difficulties in performing the procedure. Cardiologists should recognize guideline-based indications when TEE is needed and be mindful of the complication rates of this procedure. When screening a patient for TEE, consider expert input that may reduce the risks of TEE (e.g., a spine specialist for a neck injury, a gastroenterologist for esophageal comorbidity). Informed consent and medical record documentation should be practiced as a vehicle to inform patients of these risks and chronicle decision-making processes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.echo.2018.11.003DOI Listing

Publication Analysis

Top Keywords

tee
12
claims involved
12
transesophageal echocardiography
8
authors reviewed
8
claims
8
claims involving
8
involving tee
8
three claims
8
perform tee
8
tee appropriate
8

Similar Publications

Infectious myocarditis (IM) and infective endocarditis (IE), sometimes associated with infection of the surrounding mediastinal tissue or embolic complications caused by residual implantable cardioverter defibrillator (ICD) lead material embedded in the ventricle, present a significant challenge for cardiac surgeons due to the difficulty of precisely locating the old intracardiac pacing lead remnants because of the heart's continuous movement. We present the case of successful two-stage elective sternotomy extraction of two residual defibrillator leads, one trapped in the left innominate vein, easily removed after veinotomy without cardiopulmonary bypass (CPB), and the other embedded intramyocardially in the inferior wall of the right ventricle, successfully removed under CPB after fluoroscopic guidance. The patient was discharged four weeks post-operation without complications.

View Article and Find Full Text PDF

Background: The incidence and mortality rate of hepatocellular carcinoma (HCC) are increasing globally. HCC with inferior vena cava tumor thrombus (HCCIVCTT) represents an advanced stage of the disease. Research suggests that for patients with advanced HCCIVCTT, liver resection combined with thrombectomy is a safe and feasible option that can provide moderate survival benefit.

View Article and Find Full Text PDF

Background: Left atrial dissection is a rare and occasionally fatal complication of cardiac surgery and is defined as the creation of a false chamber through a tear in the mitral valve annulus extending into the left atrial wall. Some patients are asymptomatic, while others present with various symptoms, such as chest pain, dyspnea, and even cardiac arrest. Although there is no established management for left atrial dissection, surgery should be considered in patients with hemodynamic disruption.

View Article and Find Full Text PDF

Blood-brain barrier (BBB) dysfunction is suggested to be a potential mediator between vascular risk factors and cognitive impairment, leading to vascular cognitive impairment. To investigate the relationships between age, sex, and vascular risk factors and BBB water permeability as well as their relationship with cognition. To measure BBB permeability, a novel arterial spin labelling MRI technique (ME-ASL) was applied to derive the time of exchange (Tex), arterial time transit (ATT), and cerebral blood flow (CBF).

View Article and Find Full Text PDF

Objective: To determine whether a transesophageal echocardiography (TEE) probe can accurately measure temperature and be used to monitor temperature changes over time without overheating in an experimental model of hypothermia and rewarming.

Methods: A 6L water bath was heated with a sous vide immersion circulator to 24C, 28C, 32C and 36C to simulate severe hypothermia, moderate hypothermia, mild hypothermia, and normothermia. A TEE probe, esophageal temperature probe, and bladder temperature probe were used to measure temperature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!