A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dynamic MRI in the Evaluation of Atlantoaxial Stability in Pediatric Down Syndrome Patients. | LitMetric

AI Article Synopsis

  • Down syndrome is linked to atlantoaxial instability, and this study explores predictors of neurological deficits using dynamic MRI, a technology not available in previous screening guidelines.
  • A review of 36 Down syndrome patients revealed that symptomatic individuals showed more significant changes in their MRI measurements compared to asymptomatic ones, and they were more likely to have bony anomalies.
  • The findings suggest that changes over 3 mm in the atlantodental interval or over 5 mm in the space available for the cord during dynamic MRI indicate a need for more investigation to prevent unnecessary interventions for patients at low risk.

Article Abstract

Background/aims: Down syndrome is the most common inherited disorder. Some patients develop atlantoaxial instability. Existing screening guidelines were developed prior to availability of MRI. We present predictors for deficit using dynamic MRI of the craniocervical junction.

Methods: A retrospective review of Down syndrome patients from 2001 to 2015 was carried out. Patients were considered symptomatic if they had clinical deficits or signal change on MRI. Measurements were taken at the atlantoaxial junction and structural abnormalities noted. Analysis was performed with SPSS.

Results: A total of 36 patients were included. Patients averaged 93 months of age with a follow-up of 57 months. No asymptomatic patients developed myelopathy during follow-up. During dynamic imaging, symptomatic patients had greater changes in space available for the cord (SAC) (5.2 vs. 2.7 mm; p < 0.001) and atlantodental interval (ADI) (2.8 vs. 1.3 mm; p = 0.04). These patients were also more likely to have a bony anomaly (50 vs. 13%; p = 0.03).

Conclusion: This study characterizes the range of motion seen on dynamic MRI and provides parameters that can be used to distinguish patients at risk for neurologic injury. Changes greater than 3 mm in ADI or 5 mm in SAC during dynamic MRI or any bony abnormality warrants further investigation. Patients without these features may be able to avoid an unnecessary intervention.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000495788DOI Listing

Publication Analysis

Top Keywords

dynamic mri
16
patients
11
syndrome patients
8
dynamic
5
mri
5
mri evaluation
4
evaluation atlantoaxial
4
atlantoaxial stability
4
stability pediatric
4
pediatric syndrome
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!