Malaria is traditionally diagnosed by blood smear microscopy, which requires continuous resource-demanding training. In areas with only a few cases of malaria, a simple and rapid test that can reliably exclude malaria could significantly reduce the need for microscopy and training. We evaluated whether loop-mediated isothermal amplification (LAMP) for screening malaria parasites could reduce the workload in the diagnosis of malaria. Loop-mediated isothermal amplification was used to analyze 38 ethylene-diamine-tetraacetic acid (EDTA) blood samples from 23 patients who had previously been tested for malaria by microscopy, antigen-based rapid diagnostic test (antigen-RDT), and in-house real-time polymerase chain reaction (RT-PCR). The samples included blood with low-level parasitaemia and samples with discrepancies between the results of the different methods. Loop-mediated isothermal amplification detected malaria parasites in 27 of 28 samples that were positive according to in-house RT-PCR. There were negative microscopy results in 10 of these and negative antigen-RDT results in 11. The sample with a negative LAMP result and positive in-house RT-PCR result was from a patient who had recently been treated for low-level malaria parasitaemia. We found LAMP to be reliable for malaria screening and suitable for replacing microscopy without loss of performance. The low number of LAMP-positive samples needing microscopy can be handled by a limited number of trained microscopists. The time saved on training and documentation was estimated to be 520 working hours yearly in our laboratory. Using LAMP for primary screening of patient samples, we have made a diagnostic workflow that ensures more reliable, faster, and less resource-demanding diagnosis of malaria.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6402892 | PMC |
http://dx.doi.org/10.4269/ajtmh.18-0496 | DOI Listing |
Sci Rep
January 2025
Department of Biology, Faculty of Science, Naresuan University, Phitsanulok, Thailand.
Xanthomonas oryzae pv. oryzae (Xoo) is a bacterial pathogen responsible for bacterial leaf blight (BLB) in rice, which can result in significant yield losses of up to 70%. A study evaluated the spread of Xoo in rice fields using environmental samples and employed colorimetric loop-mediated amplification (cLAMP) and PCR for detection.
View Article and Find Full Text PDFAnal Chim Acta
January 2025
State Key Laboratory of Microbial Technology, Microbial Technology Institute, Shandong University, Qingdao, Shandong, 266237, China. Electronic address:
Background: The COVID-19 pandemic has significantly affected global health, economies, and societies, and highlighted the urgent need for rapid, sensitive, affordable, and portable diagnostic devices for respiratory diseases, especially in areas with limited resources. In recent years, there has been rapid development in integrated equipments using microfluidic chips and biochemical detection technologies. However, these devices are expensive and complex to operate, showing limited feasibility for in point of care tests (PoCTs).
View Article and Find Full Text PDFBiotechnol J
January 2025
School of Biology and Biological Engineering, South China University of Technology, Guangzhou, China.
Loop-mediated isothermal amplification (LAMP) is a detection method widely used in pathogen detection and clinical diagnosis. Nevertheless, it is highly constrained by thermal stability, catalytic activity, and resistance to inhibitors of Bst DNA polymerase. In this study, a novel DNA polymerase was characterized from Clostridium thermocellum, exhibiting potential in LAMP detection.
View Article and Find Full Text PDFLab Chip
January 2025
James Watt School of Engineering, University of Glasgow, Glasgow, UK.
Milk is commonly screened both for indicators of animal disease and health, but also for foodborne hazards. Included in these analyses is the detection of , that can produce an enterotoxin, causing staphylococcal food poisoning (SFP), which often leads to sudden onset of significant gastrointestinal symptoms in humans. Epidemiological data on SFP are limited, particularly in low- and middle-income countries.
View Article and Find Full Text PDFEur J Clin Microbiol Infect Dis
January 2025
Clinic for Urology, Pediatric Urology and Andrology, Justus-Liebig-University, Giessen, Germany.
Purpose: We designed and tested a point of care test panel to detect E.coli and antibiotic susceptibility in urine samples from patients at the point of care in the urological department. The aim of this approach is to facilitate choosing an appropriate antibiotic for urinary tract infections (UTI) at first presentation in the context of increasing antibiotic resistance in uropathogens worldwide.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!