A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intraoperative Parathyroid Autofluorescence Detection in Patients with Primary Hyperparathyroidism. | LitMetric

Background: Intrinsic near-infrared (NIR) autofluorescence of the parathyroid gland may improve intraoperative gland identification without the need for contrast agent injection. Compared with patients undergoing surgery for thyroid disease, identification of pathologic parathyroid tissue in patients with hyperparathyroidism is essential. This study analyzed the utility of a novel real-time autofluorescence imaging system in patients with primary hyperparathyroidism enrolled in a prospective feasibility clinical trial.

Methods: Data on patients undergoing surgery for primary hyperparathyroidism by two experienced endocrine surgeons were prospectively collected. Intraoperative imaging was performed with a handheld NIR device, and images were captured for analysis. The collected data included the surgeon's confidence in parathyroid identification, both with ambient light and use of NIR imaging, as well as how the imaging affected the surgical procedure. Images were quantified by Image J software, with autofluorescence reported as mean values ± SD.

Results: From 2017 to 2018, 59 consecutive patients with a diagnosis of primary hyperparathyroidism underwent resection of 69 parathyroid glands. Use of NIR imaging increased the intraoperative confidence of parathyroid identification (on a scale of 0-5) from an average of 4.1 to an average of 4.4 (+0.3, p = 0.003), all of which were confirmed pathologically. The addition of autofluorescence helped to identify the parathyroid gland in 12 patients (20%), and to rule out other soft tissue as not parathyroid in an additional 9 patients (15%). The mean autofluorescence for the parathyroid in situ (75.9 ± 21.3) was significantly greater than that for the thyroid (61.1 ± 17.4) or soft tissue (53.3 ± 19.2) (p < 0.001 for both). The mean absolute difference in parathyroid versus background thyroid autofluorescence was +15.2 (range, 2.4-53.1).

Conclusion: This is the first prospective trial to examine the utility of parathyroid autofluorescence for identifying glands exclusively in patients with parathyroid disease. Intraoperative identification and localization of parathyroid glands by real-time, NIR imaging using their intrinsic autofluorescence is feasible and may provide a useful adjunct during parathyroid surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1245/s10434-019-07161-wDOI Listing

Publication Analysis

Top Keywords

primary hyperparathyroidism
16
patients
8
patients primary
8
parathyroid
8
autofluorescence parathyroid
8
parathyroid gland
8
patients undergoing
8
undergoing surgery
8
confidence parathyroid
8
parathyroid identification
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!