Outcome of delayed adjustable strabismus surgery in children using a bow-tie optional adjustable technique.

Indian J Ophthalmol

The Eye Foundation, 582A DB Road, R.S. Puram, Coimbatore, India.

Published: February 2019

Purpose: The aim of this article is to study the feasibility of a delayed adjustable technique of strabismus surgery in children using an optional adjustable suture technique.

Methods: The retrospective study included patients <12 years of age. Recessions were done using an optional adjustable bow-tie technique and resections were done by the conventional technique. Patients were evaluated on the third postoperative day and adjustments done when needed. Statistical analysis was done using Microsoft Excel 2010®.

Results: The study included 11 patients with exotropia and 16 patients with esotropia. The mean age of the patients was 5.2 years (range 1-11 years). The mean preoperative distance deviation was 46.7 ± 10.4 prism diopters (PD) for exotropic patients and 47.1 ± 16.9 PD for esotropic patients. The mean preoperative near deviation was 46.6 ± 11 PD for exotropic patients and 52.4 ± 17.1 PD for esotropia. Two patients with exotropia (18.2%) and four patients with esotropia (25%) were adjusted under intravenous ketamine in the operating room under anesthetist supervision. No difficulty was encountered in advancing/recessing the muscles. The success rate at 1 month was 100% for exotropia and 87.5% for esotropia. The success rate at the final follow-up was 81.8% for patients with exotropia and 68.7% for patients with esotropia.

Conclusions: This delayed optional adjustable strabismus surgery technique provides good short-term results and lower adjustment rates.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6376808PMC
http://dx.doi.org/10.4103/ijo.IJO_398_18DOI Listing

Publication Analysis

Top Keywords

delayed adjustable
8
strabismus surgery
8
surgery children
8
optional adjustable
8
adjustable technique
8
outcome delayed
4
adjustable
4
adjustable strabismus
4
children bow-tie
4
bow-tie optional
4

Similar Publications

The application of temperature-compensated photonic device is hampered by poor accuracy and overly simplistic functions of propagation in photonic integrated circuits (PICs) field. Herein, we report a new library of donor-acceptor metal-organic framework (D-A MOF) with thermally activated delayed fluorescence (TADF) and the fabricating of temperature-compensated photonic device by virtue of the unique temperature response character of TADF emitters. Highly tunable through-space charge transfer (TSCT) of TADF was realized within the D-A MOFs through a novel strategy that synergistically combines the internal heavy atom effect (HAE) with an external HAE, induced by the incorporation of heavy atoms into different components, achieving the regulable photophysical indicators including adjustable PL wavelength (534 to 592 nm) and surging quantum yield (5.

View Article and Find Full Text PDF

Background: In this study we investigate the selective compensation of paired peripheral nerves in healthy humans, focusing on distinct axonal conduction velocities in different fibre types. Using paired associative stimulation (PAS) with adjustable parameters, we aimed to modulate and compensate for neuronal activity along the median nerve.

Methods: Six healthy volunteers (3 male, 3 female, aged: 22-49) participated in the current study.

View Article and Find Full Text PDF

An efficient injection protocol for larvae.

Biol Methods Protoc

December 2024

Department of Biological Sciences, University of Alberta, G-504 Biological Sciences Bldg, Edmonton, Alberta, Canada, T6G 2E9.

Intravenous injection provides a direct, rapid, and efficient route for delivering drugs or other substances, particularly for compounds with poor intestinal absorption or molecules (e.g. proteins) that are prone to structural changes and degradation within the digestive system.

View Article and Find Full Text PDF

Purpose: To evaluate visual and refractive outcomes in eyes with a history of radial keratotomy (RK) implanted with the second-generation light-adjustable lens (LAL).

Setting: Private practice, multiple locations.

Design: Retrospective, consecutive case series.

View Article and Find Full Text PDF

Application of microscopic smartphone attachment for remote preoperative lab testing.

Front Digit Health

November 2024

Institute for Robotics and Intelligent Machines, Georgia Institute of Technology, Atlanta, GA, United States.

Introduction: Current preoperative exam guidelines utilize extensive lab tests, including blood tests and urine analysis, which are crucial for assessing surgical readiness. However, logistical challenges, especially for patients traveling long distances for high-quality medical care, create significant delays and burdens. This study aims to address these challenges by applying a previously developed point-of-care (POC) device system to perform accurate and rapid lab tests.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!