A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Innovation in surgery/operating room driven by Internet of Things on medical devices. | LitMetric

Background: With the improvement of sensor technology, the trend of Internet of Things (IoT) is affecting the medical devices. The aim of this study is to verify whether it is possible to "visualize instrument usage in specific procedures" by automatically accumulating the digital data related to the behavior of surgical instruments/forceps in laparoscopic surgery.

Methods: Five board-certified surgeons (PGY 9-24 years) performed laparoscopic cholecystectomy on 35-kg porcine (n = 5). Radio frequency identifier (RFID) was attached to each forceps with RFID readers installed on the left/right of the operating table. We automatically recorded the behavior by tracking the operator's right/left hands' forceps with RFID. The output sensor was installed in the electrocautery circuit for automatic recordings of the ON/OFF times and the activation time. All data were collected in dedicated software and used for analysis.

Results: In all cases, the behaviors of forceps and electrocautery were successfully recorded. The median operation time was 1828 s (range 1159-2962 s), of which the electrocautery probe was the longest held on the right hand (1179 s, 75%), followed by Maryland dissectors (149 s, 10%), then clip appliers (91 s, 2%). In contrast, grasping forceps were mainly used in the left hand (1780 s, 93%). The activation time of electrocautery was only 8% of the total use and the remaining was mainly used for dissection. These situations were seen in common by all operators, but as a mentor surgeon, there was a tendency to change the right hand's instruments more frequently. The median activation time of electrocautery was 0.41 s, and these were confirmed to be 0.14-0.57 s among the operators.

Conclusion: By utilization of IoT for surgery, surgical procedure could be "visualized." This will improve the safety on surgery such as optimal usage of surgical devices, proper use of electrocautery, and standardization of the surgical procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00464-018-06651-4DOI Listing

Publication Analysis

Top Keywords

activation time
12
internet things
8
medical devices
8
forceps rfid
8
time electrocautery
8
electrocautery
6
innovation surgery/operating
4
surgery/operating room
4
room driven
4
driven internet
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!