The effect of transfixation pins on the biomechanical properties of angled acrylic connecting bars.

Can J Vet Res

Faculty of Veterinary Medicine, Ringgold Standard Institution - Clinical Sciences, University of Montreal, Saint Hyacinthe, Quebec (Montasell, Herndon, Szwec); Faculty of Veterinary Medicine, University of Montreal, Saint Hyacinthe, Quebec (Beauchamp).

Published: January 2019

With acrylic external-fixation frames for fracture repair the acrylic columns can be contoured to allow greater versatility in the placement of transfixation pins, thus minimizing damage to the surrounding soft tissue and making mandibular and transarticular fixation easier. However, contouring affects the stiffness and ultimate strength of the construct under axial compression. In this study, polymethylmethacrylate columns 21 mm in diameter angled at 0°, 30°, 45°, 60°, or 90° with clamps were constructed. For each angulation group, pins 3.2-mm long were placed in 6 columns, 2 pins at each end, 1.5 cm from each other, and 6 columns had no pins. Each column was allowed to polymerize for a minimum of 10 min, then was placed in a biomechanical-testing machine, the load cell at the bottom end of the column and the actuator on top, with a preload of 10 to 12 N to prevent slippage. The columns underwent axial loading at a rate of 8 mm/s until catastrophic failure occurred. Data on force and deformation were collected every 0.025 s. Both stiffness and ultimate strength of the column decreased significantly ( < 0.01), up to 77% and 70%, respectively, with each increase of angulation. The columns with pins were significantly less stiff ( < 0.05) than those without pins at angulations of 45° and 60°. However, the columns with pins did not show significant differences in ultimate strength from the columns without pins at any of the angulations. The point of failure was always at the angle of the column, demonstrating that in axial compression the weakest point is not the pin-acrylic interface when pins are eccentrically located within the column.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6318828PMC

Publication Analysis

Top Keywords

columns pins
20
ultimate strength
12
pins
9
transfixation pins
8
columns
8
stiffness ultimate
8
axial compression
8
45° 60°
8
pins angulations
8
column
5

Similar Publications

Article Synopsis
  • - Elbow stiffness is a rare but impactful condition often resulting from trauma, with capitellum fractures being a rare cause that can be easily misdiagnosed due to their nonspecific symptoms.
  • - A case study of a 54-year-old woman revealed significant elbow stiffness after a traumatic incident, with imaging showing a malunited capitellum; she underwent successful surgical intervention restoring full range of motion.
  • - Early detection of capitellum fractures is important to avoid complications like elbow stiffness, and advanced tools like 3D printing aid in accurate surgical planning for these complex cases.
View Article and Find Full Text PDF

Objective: To investigate global optimisation of anterior acetabular column pinning channels can be achieved based on large density point cloud data.

Methods: Data were collected on the CT scans of the normal pelvis in 40 adults from January 2022 to January 2023, including 22 males and 18 females, aged 20 to 54 years old. Medical imaging data from three of the samples were selected for experimental study.

View Article and Find Full Text PDF

The stabilization of fractures of the anterior pelvic ring and anterior column of the acetabulum with antegrade or retrograde intramedullary screws has been frequently described. However, these narrow and nonlinear bony corridors can be challenging and dangerous to accommodate with rigid linear implants. Titanium elastic nails (TEN) are ideal implants to navigate in the narrow, irregular medullary canal in this anatomical location.

View Article and Find Full Text PDF

Background: Pediatric supracondylar humerus (SCH; AO/OTA13-M/3.1) and medial epicondyle fractures (AO/OTA13u-M/7.1) are common.

View Article and Find Full Text PDF

Background: Operative management of midfoot Charcot arthropathy often involves an extended midfoot arthrodesis with intramedullary bolts for fixation, a method called "beaming." Recently intramedullary nails have been introduced for the same indication, presumably providing stronger fixation. This study compares midfoot fusion nails to bolts with regard to stiffness and compressive ability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!