A rapid UPLC-MS-MS method was developed and validated for determination of losartan in rabbit plasma. Protonated adducts of losartan and eprosartan (IS) were monitored in multiple reaction monitoring mode. Molecular masses of daughter species of losartan were m/z 423.19 > 207 and m/z 423.19 > 180; and of eprosartan were m/z 425.11 > 135 and m/z 425.11 > 107. Losartan from plasma samples was extracted by protein precipitation method. The mobile phase comprising water (0.1% formic acid) (A) and acetonitrile (0.1% formic acid) (B) was used in gradient mode. Analytes were eluted on Acquity UPLC®BEH C18 1.7 μm, 2.1 × 50 mm column. Sample run time was 3.0 min. The validation parameters: accuracy, precision and recovery were within recommended limits. Losartan as well as internal standard remains stable in benchtop stability study as well as in post-preparative stability study. Pharmacokinetic parameters such as Cmax (182.79 ± 23.80 ng/mL), Tmax (1.16 ± 0.28 h), AUC0-t (1188.57 ± 404.60 ng h/mL) and Kel (0.0954 ± 0.0140 h-1) of losartan were measured. Method was successfully applied for pharmacokinetic investigation in rabbits and can be used for losartan determination in plasma sample obtained from other animals.