The individual monitoring service at the Helmholtz Zentrum München is currently developing a new eye lens dosemeter to be integrated in radiation protection glasses and a new ring dosemeter using a new BeOSL detector element for extremity dosimetry developed by Dosimetrics. In the design process for the new eye lens dosemeter, MCNP6 Monte Carlo simulations were used to model the energy and angular response of new dosemeters before ordering the expensive tools for injection molding. This study describes the simulation of the dosemeter and detector, and the involved calculations do obtain the response in terms of the radiation protection quantity Hp(3). Simulations were carried out also for existing whole body dosemeters and TLD rings in order to verify the MC tools. With the final dosemeter prototypes becoming available earlier this year, all MC models could be verified and show very good agreement with experimental data.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncy299DOI Listing

Publication Analysis

Top Keywords

eye lens
8
lens dosemeter
8
radiation protection
8
dosemeter
6
simulation osl
4
osl tld
4
tld dosemeter
4
dosemeter response
4
response development
4
development extremity
4

Similar Publications

Femtosecond Laser Arcuate Keratotomy vs Toric Intraocular Lens Implantation in Cataract Surgery: A Randomized Clinical Trial.

JAMA Ophthalmol

January 2025

Eye Center, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Zhejiang Provincial Key Laboratory of Ophthalmology, Zhejiang Provincial Clinical Research Center for Eye Diseases, Zhejiang Provincial Engineering Institute on Eye Diseases, Hangzhou, China.

Importance: After cataract surgery, postoperative residual astigmatism can influence a patient's visual quality and satisfaction. Finding ways to minimize this astigmatism is important.

Objective: To compare the clinical outcomes of femtosecond laser arcuate keratotomy (FSAK) and toric intraocular lens (TIOL) implantation for astigmatism correction in patients undergoing femtosecond laser-assisted cataract surgery.

View Article and Find Full Text PDF

Background And Objective: This study determined whether practitioners specializing in keratoconus (KC) adhere to published guidelines for disease management and to what extent comorbid conditions of dry eye, contact lens tolerance, and psychological consequences of KC are formally assessed as part of long-term management.

Materials And Methods: This cross-sectional study used an IRB-approved, Internet-based, REDCap platform. Descriptive statistics are presented.

View Article and Find Full Text PDF

Purpose: Using a fully automated multitask deep learning method, which enabled simultaneous segmentation and quantification of all major anterior segment structures with swept-source optical coherence tomography (SS-OCT), we aimed to investigate the three-dimensional (3D) alterations in iris morphology before and after implantable collamer lens (ICL) surgery.

Methods: All enrolled patients underwent anterior segment SS-OCT (ANTERION) within one week before and after ICL surgery. A multitask network automatically performed iris SS-OCT image segmentation and quantitative measurements of 3D iris morphology (iris thickness and volume of the inner 1-mm annular area and the outer 1-2-mm annular area, iris curvature [I-Curve], and iris smooth index [SI]).

View Article and Find Full Text PDF

Purpose: Proliferative vitreoretinopathy (PVR) is a complication of retinal detachment which requires multiple vitreoretinal surgical interventions and frequent use of oil endotamponade. In this study, we conducted an in-depth analysis of complications associated with the use of heavy silicone oil in the management of inferior PVR.

Methods: A retrospective cohort study of 20 eyes that underwent vitrectomy for inferior PVR with use of heavy silicone oil (Densiron 68) between March 2021 and October 2022 at Oxford Eye Hospital.

View Article and Find Full Text PDF

Bleb-like retinal detachment (BLRD) in posterior zone 1 retinopathy of prematurity (ROP) presents a significant therapeutic challenge and is associated with a guarded visual prognosis. We present a case of a female infant born preterm with a birth weight of 1100 g. Examination revealed bilateral stage 4 aggressive ROP in posterior zone 1 with BLRD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!