A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Usability Study of 3 Radiotherapy Systems: A Comparative Evaluation Based on Expert Evaluation and User Experience. | LitMetric

A Usability Study of 3 Radiotherapy Systems: A Comparative Evaluation Based on Expert Evaluation and User Experience.

Med Sci Monit

Department of Medical Engineering, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China (mainland).

Published: January 2019

BACKGROUND The complex user interface design of radiotherapy treatment delivery systems can lead to use error and patient harm. In this study, we present the results of a comparison of 3 radiotherapy treatment delivery systems now used in China. MATERIAL AND METHODS We conducted a comprehensive usability study of 3 radiotherapy treatment delivery systems. Expert evaluation was performed through heuristic evaluation with 3 human-factors experts and 1 experienced radiation therapist for each system. User experience was assessed through perceived system usability and workload, using the National Aeronautics and Space Administration Task Load Index and the Post-Study System Usability Questionnaire. RESULTS For the expert evaluation, 47 usability problems were identified for Varian Trilogy, 75 for Elekta Precise, and 37 for Shinva XHA600E. Most problems were classified as major and minor usability problems, and were found in the process of patient setup and setup verification. For the user experience, radiation therapists presented a lower workload for Varian Trilogy compared to Elekta Precise (P<0.01) and Shinva XHA600E (P<0.01), and a lower workload for Elekta Precise compared to Shinva XHA600E (P=0.020). Radiation therapists perceived a higher system usability for Varian Trilogy compared to Shinva XHA600E (P<0.01), and a higher system usability for Elekta Precise compared to Shinva XHA600E (P<0.01). CONCLUSIONS This research provides valuable data on how 3 radiotherapy treatment delivery systems compare. The results of this study may be useful for hospital equipment procurement decisions, and designing next-generation products to improve patient safety.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6348750PMC
http://dx.doi.org/10.12659/MSM.913160DOI Listing

Publication Analysis

Top Keywords

expert evaluation
12
user experience
12
radiotherapy treatment
12
treatment delivery
12
delivery systems
12
usability study
8
study radiotherapy
8
system usability
8
usability problems
8
varian trilogy
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!