Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
BACKGROUND The complex user interface design of radiotherapy treatment delivery systems can lead to use error and patient harm. In this study, we present the results of a comparison of 3 radiotherapy treatment delivery systems now used in China. MATERIAL AND METHODS We conducted a comprehensive usability study of 3 radiotherapy treatment delivery systems. Expert evaluation was performed through heuristic evaluation with 3 human-factors experts and 1 experienced radiation therapist for each system. User experience was assessed through perceived system usability and workload, using the National Aeronautics and Space Administration Task Load Index and the Post-Study System Usability Questionnaire. RESULTS For the expert evaluation, 47 usability problems were identified for Varian Trilogy, 75 for Elekta Precise, and 37 for Shinva XHA600E. Most problems were classified as major and minor usability problems, and were found in the process of patient setup and setup verification. For the user experience, radiation therapists presented a lower workload for Varian Trilogy compared to Elekta Precise (P<0.01) and Shinva XHA600E (P<0.01), and a lower workload for Elekta Precise compared to Shinva XHA600E (P=0.020). Radiation therapists perceived a higher system usability for Varian Trilogy compared to Shinva XHA600E (P<0.01), and a higher system usability for Elekta Precise compared to Shinva XHA600E (P<0.01). CONCLUSIONS This research provides valuable data on how 3 radiotherapy treatment delivery systems compare. The results of this study may be useful for hospital equipment procurement decisions, and designing next-generation products to improve patient safety.