A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effects of passive leg raising may be detected by the plethysmographic oxygen saturation signal in critically ill patients. | LitMetric

The effects of passive leg raising may be detected by the plethysmographic oxygen saturation signal in critically ill patients.

Crit Care

Service de réanimation-médecine intensive, Centre Hospitalier Universitaire de Bicêtre, Hôpitaux universitaires Paris-Sud, Assistance publique - Hôpitaux de Paris, 78, rue du Général Leclerc, F-94 270, Le Kremlin-Bicêtre, France.

Published: January 2019

AI Article Synopsis

  • The study investigates the use of the perfusion index (PI) as a non-invasive predictor of positive results in the passive leg raising (PLR) test, traditionally measured using cardiac index (CI).
  • It involved 72 patients with acute circulatory failure, revealing that an increase in PI by over 9% during PLR correlates strongly with a significant rise in CI.
  • The findings suggest that monitoring PI could be an effective way to assess preload responsiveness in patients without needing direct CI measurements.

Article Abstract

Background: A passive leg raising (PLR) test is positive if the cardiac index (CI) increased by > 10%, but it requires a direct measurement of CI. On the oxygen saturation plethysmographic signal, the perfusion index (PI) is the ratio between the pulsatile and the non-pulsatile portions. We hypothesised that the changes in PI could predict a positive PLR test and thus preload responsiveness in a totally non-invasive way.

Methods: In patients with acute circulatory failure, we measured PI (Radical-7) and CI (PiCCO2) before and during a PLR test and, if decided, before and after volume expansion (500-mL saline).

Results: Three patients were excluded because the plethysmography signal was absent and 3 other ones because it was unstable. Eventually, 72 patients were analysed. In 34 patients with a positive PLR test (increase in CI ≥ 10%), CI and PI increased during PLR by 21 ± 10% and 54 ± 53%, respectively. In the 38 patients with a negative PLR test, PI did not significantly change during PLR. In 26 patients in whom volume expansion was performed, CI and PI increased by 28 ± 14% and 53 ± 63%, respectively. The correlation between the PI and CI changes for all interventions was significant (r = 0.64, p < 0.001). During the PLR test, if PI increased by > 9%, a positive response of CI (≥ 10%) was diagnosed with a sensitivity of 91 (76-98%) and a specificity of 79 (63-90%) (area under the receiver operating characteristics curve 0.89 (0.80-0.95), p < 0.0001).

Conclusion: An increase in PI during PLR by 9% accurately detects a positive response of the PLR test.

Trial Registration: ID RCB 2016-A00959-42. Registered 27 June 2016.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6339274PMC
http://dx.doi.org/10.1186/s13054-019-2306-zDOI Listing

Publication Analysis

Top Keywords

plr test
20
passive leg
8
leg raising