Background: Data on bioresorbable vascular scaffolds (BVS) for the treatment of long lesions are limited. We studied the use of BVS-Absorb in routine clinical practice and compared the outcome of long lesions with short lesions. Implantation of drug-eluting scaffolds without PSP-technique (predilation, proper sizing and postdilation) is associated with an increased thrombotic risk. We compared the long-term outcome up to 36 months of patients with short (< 20 mm) and long (≥20 mm) coronary artery lesions after implantation of bioresorbable vascular scaffolds (BVS) via PSP-technique.

Methods: Three hundred twenty-six patients with 424 lesions were enrolled in this prospective study and underwent percutaneous coronary intervention with the Absorb BVS. Clinical follow-up was scheduled after 12, 24 and 36 months. In all lesions the PSP-technique was used. The device oriented composite endpoint (DOCE) was defined as cardiac death, myocardial infarction (MI) not clearly related to a non-target vessel and target lesion revascularization (TLR).

Results: Kaplan-Meier estimates for DOCE after 12 months were 2.63% for short lesions and 8.09% for long lesions (p = 0.0131), 5.51% vs. 11.35% (p = 0.0503) after 24 months and 8.00% vs. 18.00% (p = 0.0264) after 36 months of clinical follow-up. Kaplan-Meier estimates for TLR after 12 months were 1.46% for short and 7.69% for long lesions (p = 0.0012), 2.06% vs. 8.75% after 24 months (p = 0.0027) and 4.96% vs. 9.59% after 36 months of follow-up (p = 0.0109). Scaffold thrombosis rates were low.

Conclusions: In long lesions compared to short ones the bioresorbable scaffold Absorb implanted with the proper PSP technique Absorb has significant higher rates of DOCE.

The Level Of Evidence: Is 3 (non-random sample).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6339442PMC
http://dx.doi.org/10.1186/s12872-018-0994-yDOI Listing

Publication Analysis

Top Keywords

drug-eluting scaffolds
8
long lesions
8
clinical bioresorbable
4
bioresorbable drug-eluting
4
scaffolds short
4
short long
4
long coronary
4
coronary artery
4
lesions
4
artery lesions
4

Similar Publications

Biodegradable Stents in the Treatment of Arterial Stenosis.

J Clin Med

January 2025

Department of Accident and Emergency, Etlik City Hospital, Ankara 06170, Turkey.

Arterial diseases (ADs) are a significant health problem, with high mortality and morbidity rates. Endovascular interventions, such as balloon angioplasty (BA), bare-metal stents (BMSs), drug-eluting stents (DESs) and drug-coated balloons (DCBs), have made significant progress in their treatments. However, the issue has not been fully resolved, with restenosis remaining a major concern.

View Article and Find Full Text PDF

Purpose: Treatment of peripheral artery disease (PAD) in the region below the knee (BTK) is dissatisfying as failure of treated target lesions (TLF) is frequent and diagnostic imaging is often challenging. In the BTK-region metallic drug-eluting stents (mDES) yielded best results concerning primary patency (PP), but also annihilate signal in magnetic resonance angiography (MR-A). A recently introduced non-metallic drug eluting bioresorbable Tyrocore® vascular scaffold (deBVS), that offers an option for re-treatment of lesions due to its full degradation within 3-4 years after placement, was investigated with respect to its compatibility with MR-A to unimpededly depict previously treated target lesions.

View Article and Find Full Text PDF

Background: Bioresorbable scaffolds (BRS) were developed to overcome limitations related to late stent failures of drug-eluting stents, but lumen reductions over time after implantation of BRS have been reported. This study aimed to investigate if lesion preparation with a scoring balloon compared with a standard noncompliant balloon minimizes lumen reduction after implantation of a Magmaris BRS assessed with optical coherence tomography and intravascular ultrasound.

Methods: Eighty-two patients with stable angina were randomized in a ratio of 1:1 to lesion preparation with a scoring balloon versus a standard noncompliant balloon before implantation of a Magmaris BRS.

View Article and Find Full Text PDF

Background: First-generation bioresorbable scaffolds (BRS) increased risks of stent thrombosis and adverse events. The Bioheart scaffold is a new poly-L-lactic acid-based BRS.

Objectives: This study sought to evaluate the efficacy and safety of the BRS in patients with coronary artery disease.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!