A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diagnostic value of three-dimensional saline infusion sonohysterography in the evaluation of the uterus and uterine cavity lesions. | LitMetric

Purpose: The purpose of this review is to illustrate and discuss the seldom used technique of three-dimensional (3D) saline infusion sonohysterography (SIS) based on instillation of sterile saline through a catheter into the uterus under real-time vaginal transducer observation for assessment of the endometrial cavity.

Material And Methods: The cases for this pictorial review were selected from the imaging material collected at the Ultrasound Unit, Clinical Imaging Department, Women's Hospital of Hamad Medical Corporation during a seven-year period from 2011 to 2017. This was a retrospective collection of 216 consecutive cases that underwent two-dimensional (2D) and 3D SIS for evaluation of the uterine cavity, followed by verification of results with histopathology. An open-sided speculum is inserted into the vagina. An intrauterine catheter is then threaded into the endometrial cavity. After that, the speculum is removed carefully, and a vaginal transducer is inserted. Using a 60-ml syringe attached to the catheter, saline solution is instilled under direct real-time observation (2D SIS). Subsequently, reconstruction of the three-dimensional anatomy of the intrauterine cavity is performed.

Pictorial Review: The review presents the most common indication for SIS, like abnormal bleeding in pre- and postmenopausal patients. SIS allows us to distinguish between focal lesions and global endometrial thickening. SIS should be supported as a second-line diagnostic procedure for abnormal uterine bleeding, when findings from transvaginal ultrasound are inconclusive.

Conclusions: The addition of 3D techniques to SIS procedure helps in the distinction between endometrial and myometrial lesions, also it facilitates delineation of uterine anatomy, resulting in more precise and accurate diagnosis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6334128PMC
http://dx.doi.org/10.5114/pjr.2018.80132DOI Listing

Publication Analysis

Top Keywords

three-dimensional saline
8
saline infusion
8
infusion sonohysterography
8
uterine cavity
8
vaginal transducer
8
sis
7
diagnostic three-dimensional
4
saline
4
sonohysterography evaluation
4
evaluation uterus
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!