Background And Purpose: Both C-methionine PET/CT and DSC-PWI could be used to differentiate radiation injury from recurrent brain tumors. Our aim was to assess the performance of MET PET/CT and DSC-PWI for differentiation of recurrence and radiation injury in patients with high-grade gliomas and to quantitatively analyze the diagnostic values of PET and PWI parameters.

Materials And Methods: Forty-two patients with high-grade gliomas were enrolled in this study. The final diagnosis was determined by histopathologic analysis or clinical follow-up. PWI and PET parameters were recorded and compared between patients with recurrence and those with radiation injury using Student tests. Receiver operating characteristic and logistic regression analyses were used to determine the diagnostic performance of each parameter.

Results: The final diagnosis was recurrence in 33 patients and radiation injury in 9. PET/CT showed a patient-based sensitivity and specificity of 0.909 and 0.556, respectively, while PWI showed values of 0.667 and 0.778, respectively. The maximum standardized uptake value, mean standardized uptake value, tumor-to-background maximum standardized uptake value, and mean relative CBV were significantly higher for patients with recurrence than for patients with radiation injury. All these parameters showed a high discriminative power in receiver operating characteristic analysis. The optimal cutoff values for the tumor-to-background maximum standardized uptake value and mean relative CBV were 1.85 and 1.83, respectively, and corresponding sensitivities and specificities for the diagnosis of recurrence were 0.97 and 0.667 and 0.788 and 0.88, respectively. Areas under the curve for the tumor-to-background maximum standardized uptake value and mean relative CBV were 0.847 ± 0.077 and 0.845 ± 0.078, respectively. Combined assessment of the tumor-to-background maximum standardized uptake value and mean relative CBV showed the largest area under the curve (0.953 ± 0.031), with corresponding sensitivity and specificity of 0.848 and 1.0, respectively.

Conclusions: Both C-methionine PET/CT and PWI are equally accurate in the differentiation of recurrence from radiation injury in patients with high-grade gliomas, and a combination of the 2 modalities could result in increased diagnostic accuracy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7028634PMC
http://dx.doi.org/10.3174/ajnr.A5952DOI Listing

Publication Analysis

Top Keywords

radiation injury
28
standardized uptake
24
maximum standardized
20
recurrence radiation
16
patients high-grade
16
high-grade gliomas
16
tumor-to-background maximum
16
uptake relative
16
relative cbv
16
c-methionine pet/ct
12

Similar Publications

The clinical application of doxorubicin (DOX) is limited due to its cardiotoxicity, which is primarily attributed to its interaction with iron in mitochondria, leading to lipid peroxidation and myocardial ferroptosis. This study aimed to investigate the role of the gut microbiota-derived metabolite, indole-3-lactic acid (ILA), in mitigating DOX-induced cardiotoxicity (DIC). Cardiac function, pathological changes, and myocardial ferroptosis were assessed in vivo.

View Article and Find Full Text PDF

Normal tissue reactions vary significantly among patients receiving the same radiation treatment regimen, reflecting the multifactorial etiology of late radiation toxicity. Predicting late radiation toxicity is crucial, as it aids in the initial decision-making process regarding the treatment modalities. For patients undergoing radiotherapy, anticipating late toxicity allows for planning adjustments to optimize individualized care.

View Article and Find Full Text PDF

(1) Background: Volumetric modulated arc therapy (VMAT) can deliver more accurate dose distribution and reduce radiotherapy-induced toxicities for postoperative cervical and endometrial cancer. This study aims to retrospectively analyze the relationship between dosimetric parameters of organs at risk (OARs) and acute toxicities and provide suggestions for the dose constraints. (2) Methods: A total of 164 postoperative cervical and endometrial cancer patients were retrospectively analyzed, and the endpoints were grade ≥ 2 acute urinary toxicity (AUT) and acute lower gastrointestinal toxicity (ALGIT).

View Article and Find Full Text PDF

Purpose: To report the occurrence of acute postrenal kidney failure caused by external ureteral obstruction after iliac venous stent placement.

Case Report: A 73-year-old male patient presented with a chronic swelling and feeling of heaviness of his right leg. The presence of venous thrombosis was excluded by duplex ultrasound (DUS).

View Article and Find Full Text PDF

Background: Hypothyroidism is a common sequela after radiotherapy for nasopharyngeal carcinoma (NPC). Magnetic resonance imaging (MRI) has gained prominence in thyroid imaging, leveraging its non-ionizing radiation, high spatial resolution, multiparameter and multidirectional imaging. Few previous studies have investigated the evaluation of radiation-induced thyroid injury by MRI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!