Although endoscopic ultrasound (EUS)-guided transmural drainage of pancreatic fluid collections with metal stents is generally preferred over plastic stents, its superiority among different types of metal stents has not yet been well studied. We conducted this study to compare clinical outcomes and complications of a novel self-expanding biflanged metal stent (BFMS) and a traditional-shaped tubular metal stent (TMS) in treating pancreatic pseudocyst (PPC).This was a retrospective analysis on consecutive patients with PPC underwent EUS-guided transmural drainage with either TMS or BFMS in a single tertiary center with expertise in management of complex biliary and pancreatic problems. The technical and functional success rate, reintervention, complications, and recurrence rate were evaluated.From September 2013 to January 2018, 125 patients (66.4% male, median age 47 years) underwent EUS-guided transmural drainage for PPC. Among them, 49 used TMS and 76 used BFMS. All patients met the inclusion criteria that cyst diameter was >6 cm or the distance between cyst and stomach wall was shorter than 1 cm. There was no difference in technical success (98% vs 97.4%, P = 1.0) or functional success rate (87.8% vs 92.1%, P = .54) using 2 types of metal stents. However, more procedure related complications occurred in TMS than in BFMS group. TMS group had a much higher migration rate than BFMS group (14.6% vs 0, P = .001), even though there was no significant difference in bleeding, infection, or death rate between 2 groups. With similar clinical outcomes, TMS group required more additional plastic stent placement than BFMS group for better drainage.TMS and BFMS placement can both be considered as methods of endoscopic transmural PPC drainage with equal efficacy, whereas BFMS could be preferred for fewer complications or less need of additional plastic stent placement.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6370115 | PMC |
http://dx.doi.org/10.1097/MD.0000000000014179 | DOI Listing |
Ann Vasc Surg
January 2025
University of Sao Paulo (USP), Division of Vascular Surgery, Department of Medicine, Sao Paulo, Brazil.
Introduction: The main treatment for Chronic Mesenteric Ischemia (CMI) is revascularization, typically achieved through stent angioplasty of the superior mesenteric artery, and in certain cases, the celiac trunk. However, long-term outcomes using bare-metal stents have been less than satisfactory. Therefore, we aimed to compare the performance of covered stents (CS) versus bare-metal stents (BMS) in patients treated for CMI.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Accident and Emergency, Etlik City Hospital, Ankara 06170, Turkey.
Arterial diseases (ADs) are a significant health problem, with high mortality and morbidity rates. Endovascular interventions, such as balloon angioplasty (BA), bare-metal stents (BMSs), drug-eluting stents (DESs) and drug-coated balloons (DCBs), have made significant progress in their treatments. However, the issue has not been fully resolved, with restenosis remaining a major concern.
View Article and Find Full Text PDFJ Clin Med
January 2025
Division of Gastroenterology and Hepatology, Center for Digestive Health, Virginia Mason, Franciscan Health, Seattle, WA 98101, USA.
Endoscopic management of benign pancreaticobiliary disorders encompasses a range of procedures designed to address complications in gallstone disease, choledocholithiasis, and pancreatic disorders. Acute cholecystitis is typically treated with cholecystectomy or percutaneous drainage (PT-GBD), but for high-risk or future surgical candidates, alternative decompression methods, such as endoscopic transpapillary gallbladder drainage (ETP-GBD), and endoscopic ultrasound (EUS)-guided gallbladder drainage (EUS-GBD), are effective. PT-GBD is associated with significant discomfort as well as variable adverse event rates.
View Article and Find Full Text PDFDig Dis Sci
January 2025
Digestive Disease Center, Department of Internal Medicine, CHA Bundang Medical Center, CHA University, Seongnam, Republic of Korea.
Background And Aim: Stent placement for biliary drainage in patients with malignant hilar biliary obstruction (MHBO) has been a topic of long-standing debate, and the best approach remains controversial. Therefore, we aimed to evaluate the efficacy, safety, and removability of multi-hole fully covered self-expandable metal stents (MH-FCSEMSs) in a preclinical experiment using swine hilar bile duct obstruction (HBDO) models and to assess the feasibility and safety of stent placement in patients with MHBO.
Methods: Three minipigs underwent endoscopic retrograde cholangiopancreatography (ERCP)-guided endobiliary-radio frequency ablation (EB-RFA) to establish Bismuth type II hilar bile duct stenosis models.
PLoS One
January 2025
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Purpose: Treatment of peripheral artery disease (PAD) in the region below the knee (BTK) is dissatisfying as failure of treated target lesions (TLF) is frequent and diagnostic imaging is often challenging. In the BTK-region metallic drug-eluting stents (mDES) yielded best results concerning primary patency (PP), but also annihilate signal in magnetic resonance angiography (MR-A). A recently introduced non-metallic drug eluting bioresorbable Tyrocore® vascular scaffold (deBVS), that offers an option for re-treatment of lesions due to its full degradation within 3-4 years after placement, was investigated with respect to its compatibility with MR-A to unimpededly depict previously treated target lesions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!