Bioreactors have been used both to develop new, and to improve bioprocess yields for, biopharmaceutical products. However, efforts to miniaturize bioreactors, in order to save costs and accelerate process development times, have been limited by the lack of on-site monitoring capabilities available at such scales. In this study, small volume (3 nL) nonconsumptive holographic sensors were integrated into a glass-PDMS microfluidic chip to monitor via a blue-shift in the resultant holographic replay wavelength, the change in pH during microbial growth of Lactobacillus casei ( L. casei) Shirota. Within the optimal growth pH range of L. casei, the accuracy of the miniaturized pH sensors was comparable to that of a conventional pH meter. Conceivably, this approach could be extrapolated to an array of miniaturized holographic sensors sensitive to different analytes, and thereby paving the way for reliable, real-time, noninvasive monitoring of microorganisms in a nanobioreactor.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acssensors.8b01470 | DOI Listing |
Aerosp Med Hum Perform
November 2024
Introduction: As next-generation space exploration missions require increased autonomy from crews, real-time diagnostics of astronaut health and performance are essential for mission operations, especially for determining extravehicular activity readiness. An augmented reality (AR) system may be a viable tool allowing holographic visual cueing to replace physical objects used in traditional assessments.
Methods: In this study, 20 healthy adults were compared in an Ingress and Egress Task and Obstacle Weave Task with holographic and physical objects to determine the effect of AR on performance.
Nanophotonics
January 2024
School of Physics and Astronomy, Monash University, Clayton, Victoria 3800, Australia.
Sensors (Basel)
November 2024
Department of Computer Science, University of Maryland, College Park, MD 20742, USA.
Lensless microscopy is an imaging technique that allows high-resolution imaging over a large field of view with a cost-effective design. Conventional lensless microscopy often utilizes multi-height phase retrieval and pixel-super-resolution algorithms to reconstruct high-resolution images, requiring mechanical stages for three-dimensional relative movements between a light source, camera, and sample. However, the excessive use of stages inevitably increases the bulkiness of the system and extends the image acquisition time.
View Article and Find Full Text PDFTwo analog holographic wavefront sensors, for measurement of defocus, have been fabricated as both thin and volume phase transmission holograms in a self-developing photopolymer. This represents the first reported direct comparison of hologram regimes when designed for wavefront sensing. An analysis of the effect of crosstalk in the presence of one other aberration mode (astigmatism X (0/90°), coma X (horizontal), and primary spherical aberration) was carried out with each version of the sensor.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!