Computer-assisted stereotactic biopsy of intracranial lesions in pediatric patients.

Pediatr Neurosci

Department of Neurologic Surgery, Mayo Clinic, Rochester, Minn.

Published: March 1989

A computer-assisted stereotactic biopsy technique has been used in 30 patient (ages 5 months to 16 years) with intracranial lesions (supratentorial in 23 and infratentorial in 7). The computer program integrates stereotactically gathered imaging data and permits preoperative planning of a biopsy trajectory. Diagnostic tissue was obtained in 27 cases. In 2 cases, therapeutic interventions--third ventriculostomy and cyst aspiration--were accomplished at the time of the biopsy. There were no major complications related to the procedure; however, 2 patients had transient neurologic deficits. Computer-assisted stereotactic biopsy is a valuable diagnostic procedure in the pediatric patient with an intracranial lesion.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000120359DOI Listing

Publication Analysis

Top Keywords

computer-assisted stereotactic
12
stereotactic biopsy
12
intracranial lesions
8
biopsy
5
biopsy intracranial
4
lesions pediatric
4
pediatric patients
4
patients computer-assisted
4
biopsy technique
4
technique patient
4

Similar Publications

Impact of diaphragm motion on dosimetry in lower thoracic spine stereotactic body radiotherapy.

Phys Med

January 2025

Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.

Background And Purpose: Free-breathing computed tomography (FBCT) used in treatment planning for lower thoracic (Th8-Th12) spine stereotactic body radiotherapy (SBRT) can cause deviations between planned and irradiated doses due to diaphragm movement (DM). This study analyzed the dosimetric impact of DM on lower thoracic spine SBRT.

Materials And Methods: Data were collected from 19 patients who underwent FBCT and four-dimensional CT (4DCT) during the same session.

View Article and Find Full Text PDF

Background/aim: HyperArc (HA) is an automated planning technique enabling single-isocenter brain stereotactic radiotherapy (SRT); however, dosimetric outcomes may be influenced by the planner's expertise. This study aimed to assess the impact of institutional experience on the plan quality of HA-SRT for both single and multiple brain metastases.

Materials And Methods: Twenty patients who underwent HA-SRT for single metastasis between 2020 and 2021 comprised the earlier group, while those treated between 2022 and 2024 constituted the later group.

View Article and Find Full Text PDF

An MRI-guided stereotactic neurosurgical robotic system for semi-enclosed head coils.

J Robot Surg

December 2024

National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, 100084, China.

Magnetic resonance imaging (MRI) offers high-quality soft tissue imaging without radiation exposure, which allows stereotactic techniques to significantly improve outcomes in cranial surgeries, particularly in deep brain stimulation (DBS) procedures. However, conventional stereotactic neurosurgeries often rely on mechanical stereotactic head frames and preoperative imaging, leading to suboptimal results due to the invisibility and the contact with patient's head, which may cause additional harm. This paper presents a frameless, MRI-guided stereotactic neurosurgical robotic system.

View Article and Find Full Text PDF

We present a patient treated with personalized ultra-fractionated stereotactic adaptive radiotherapy (PULSAR) for non-small cell lung cancer (NSCLC) using the adaptive Varian Ethos™ system equipped with the novel HyperSight imaging platform. Three pulses of 12 Gy were separated by a pause of four weeks during which the tumor was given enough time to respond to treatment. Only initial planning computed tomography (CT) was acquired on a CT simulator (Siemens Somatom Definition Edge), whereas other pulses were adapted using online cone beam computed tomography (CBCT) images (iCBCT Acuros reconstruction) acquired while the patient was lying on the treatment couch and delivered immediately.

View Article and Find Full Text PDF

Background: Navigation surgical systems have been widely used in spinal fusion to ensure accuracy and safety during pedicle screw insertion.

Methods: The research was performed under laboratory conditions, using stereotactic navigation, surgical instruments for spinal fusion, development of additional devices and software. During the experiments, all stages of the computed tomography-guided navigation system use were performed-preoperative preparation of patient data and planning to provide visual control of the navigation of surgical instruments during the insertion of screws.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!