If the vendor's representative beam data (RBD) for TrueBeam linear accelerators are to be valid for use in clinical practice, the variations in the beam data used for beam modeling must be small. Although a few studies have reported the variation of the beam data of the TrueBeam machines, the numbers of machines analyzed in those studies were small. In this study, we investigated the variation in the beam data for 21 TrueBeam machines collected from 17 institutions with their agreement. In the exponential regions, the percent depth dose (PDD) values showed very small variation, <1% for all the photon energies analyzed. Similarly, the off-center ratio (OCR) values also showed small variation for all energies. In the field regions, the standard deviations of the values of dose difference (DD) between the data for each machine and the study average were <1% for field sizes ≥100 × 100 mm . The maximum distance-to-agreement from the average data was <0.5 mm in the penumbra regions. The output factor (OPF) values also showed very small variation (<1%) for all energies and field sizes. Both the PDD and OCR of the average study data showed good agreement with the vendor's RBD for field sizes ≥100 × 100 mm . The OPF of the average study data also showed good agreement with the vendor's RBD for all field sizes. However, although all the institutions used ionization chambers with similar cavity volumes, the 30 × 30 mm field size showed large DD variations (≥2%) in OCR in the field regions. We conclude that the intermachine variability of TrueBeam linear accelerators was very small except for small field dosimetry, supporting the validity of the use of the RBD for clinical applications. The use of the vendor's RBD might greatly facilitate the quick installation of a new linear accelerator.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6370991 | PMC |
http://dx.doi.org/10.1002/acm2.12518 | DOI Listing |
Am J Orthod Dentofacial Orthop
February 2025
Department of Orthodontics, Faculty of Dentistry, Çanakkale Onsekiz Mart University, Çanakkale, Turkey.
Introduction: This study aimed to assess the precision of an open-source, clinician-trained, and user-friendly convolutional neural network-based model for automatically segmenting the mandible.
Methods: A total of 55 cone-beam computed tomography scans that met the inclusion criteria were collected and divided into test and training groups. The MONAI (Medical Open Network for Artificial Intelligence) Label active learning tool extension was used to train the automatic model.
Sensors (Basel)
January 2025
Department of Civil Engineering, Myongji College, Seoul 03656, Republic of Korea.
Conventional approaches for the structural health monitoring of infrastructures often rely on physical sensors or targets attached to structural members, which require considerable preparation, maintenance, and operational effort, including continuous on-site adjustments. This paper presents an image-driven hybrid structural analysis technique that combines digital image processing (DIP) and regression analysis with a continuum point cloud method (CPCM) built on a particle-based strong formulation. Polynomial regressions capture the boundary shape change due to the structural loading and precisely identify the edge and corner coordinates of the deformed structure.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
CNR-IOM-Istituto Officina dei Materiali, Consiglio Nazionale delle Ricerche, 34149 Trieste, Italy.
Hybrid systems consisting of highly transparent channels of low-dimensional semiconductors between superconducting elements allow the formation of quantum electronic circuits. Therefore, they are among the novel material platforms that could pave the way for scalable quantum computation. To this aim, InAs two-dimensional electron gases are among the ideal semiconductor systems due to their vanishing Schottky barrier; however, their exploitation is limited by the unavailability of commercial lattice-matched substrates.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthodontics, Faculty of Dentistry, Ataturk University, 25030 Erzurum, Turkey.
: The aim of this prospective study was to assess the effects of rapid maxillary expansion (RME) and/or face mask (FM) treatments on the pharyngeal airway in patients with skeletal Class III malocclusion caused by maxillary deficiency. This study utilized cone beam computed tomography (CIBT) for a three-dimensional (3D) analysis of airway changes, comparing the results with those of a control group consisting of untreated skeletal Class III patients. : The study included 60 participants (34 boys, 26 girls) aged 9 to 14 years, all diagnosed with skeletal Class III malocclusion due to maxillary underdevelopment.
View Article and Find Full Text PDFCancers (Basel)
January 2025
Department of Radiation Oncology, Sharett Institute of Oncology Hadassah Medical Center, Jerusalem 91120, Israel.
Retrospective studies suggest that local radiotherapy on the prostate improves overall survival in the metastatic setting, but its benefit in patients with high-burden metastatic disease is still uncertain. We conducted a retrospective study of 100 high-metastatic-burden prostate cancer patients at Hadassah Ein Karem Medical Center from 2004 to 2021. Patients receiving local RT alongside standard treatment were compared to those receiving standard treatment alone.