Scintillator based radiation detectors readout by SiPMs successively break records in their reached time resolution. Nevertheless, new challenges in time of flight positron emission tomography (TOF-PET) and high energy physics are setting unmatched goals in the 10 ps range. Recently it was shown that high frequency (HF) readout of SiPMs significantly improves the measured single photon time resolution (SPTR), allowing to evaluate the intrinsic performance of large area devices; e.g. FBK NUV-HD SiPMs of [Formula: see text] mm area and 40 [Formula: see text]m single photon avalanche diode (SPAD) size achieve 90 ps FWHM. In TOF-PET such readout allows to lower the leading edge detection threshold, so that the fastest photons produced in the crystal can be utilized. This is of utmost importance if a high SPTR and prompt Cherenkov light generated by the hot-recoil electron upon 511 keV photo-absorption should improve timing. This paper shows that high-frequency bipolar transistor readout of state-of-the-art SiPMs coupled to high-performance scintillators can substantially improve the best achievable coincidence time resolution (CTR) in TOF-PET. In this context a CTR of 158 [Formula: see text] 3 ps FWHM with [Formula: see text] mm BGO crystals coupled to FBK SiPMs is achieved. This faint Cherenkov signal is as well present in standard LSO scintillators, which together with low SPTR values (<90 ps FWHM) improves the CTR of [Formula: see text] mm LSO:Ce:Ca coupled to FBK NUV-HD [Formula: see text] mm with 25 [Formula: see text]m SPAD size to 61 [Formula: see text] 2 ps FWHM using HF-electronics, as compared to 73 [Formula: see text] 2 ps when readout by the NINO front-end ASIC. When coupling the LSO:Ce:Ca crystals to FBK NUV-HD SiPMs of [Formula: see text] mm and 40 [Formula: see text]m SPAD size, using HF-electronics, a CTR of even 58 [Formula: see text] 3 ps for [Formula: see text] mm and 98 [Formula: see text] 3 ps for [Formula: see text] mm is achieved. This new experimental data will allow to further discuss the timing limits in scintillator-based detectors.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6560/aafd52 | DOI Listing |
JACC Clin Electrophysiol
December 2024
Physiology, Amsterdam Cardiovascular Sciences, Heart Failure, and Arrhythmias, Amsterdam University Medical Center, location Vrije Universiteit Amsterdam, Amsterdam, the Netherlands. Electronic address:
Background: Atrial fibrillation (AF) persistence is associated with molecular remodeling that fuels electrical conduction abnormalities in atrial tissue. Previous research revealed DNA damage as a molecular driver of AF.
Objectives: This study sought to explore the diagnostic value of DNA damage in atrial tissue and blood samples as an indicator of the prevalence of electrical conduction abnormalities and stage of AF.
J Clin Med
January 2025
Department of Gastroenterology, Hepatology & Nutrition, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
: Immune-mediated colitis (IMC) is a common immune-related adverse event during immune checkpoint inhibitor (ICI) therapy. This case series and review aimed to highlight atypical cases of IMC and explore the potential of PET/CT to predict imminent ICI colitis. : Through a descriptive, retrospective study at a tertiary cancer center, we identified adult patients receiving ICIs for any cancer between 2010 and 2022 who also underwent PET/CT for routine cancer surveillance during this time.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Pediatric Cardiology, Istanbul Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital, University of Health Sciences, Istanbul 34303, Turkey.
: Cardiac magnetic resonance (CMR) plays a central role in the diagnosis and follow-up of acute myocarditis (AM). In this study, we aimed to evaluate baseline and follow-up CMR findings and associated factors in children with AM. : A retrospective analysis of CMR in pediatric patients with clinical presentations suggestive of myocarditis was performed.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Huawei Technologies Co., Ltd., Chengdu 610000, China.
Metasurface-based imaging is attractive due to its low hardware costs and system complexity. However, most of the current metasurface-based imaging systems require stochastic wavefront modulation, complex computational post-processing, and are restricted to 2D imaging. To overcome these limitations, we propose a scanning virtual aperture imaging system.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Meteorology and Fluid Science Division, Central Research Institute of Electric Power Industry, 1646 Abiko, Abiko-shi 270-1194, Chiba, Japan.
The electrical resistance (ER) method is widely used for atmospheric corrosion measurements and can be used to measure the corrosion rate accurately. However, severe errors occur in environments with temperature fluctuations, such as areas exposed to solar radiation, preventing accurate temporal corrosion rate measurement. To decrease the error, we developed an improved sensor composed of a reference metal film and an overlaid sensor metal film to cancel temperature differences between them.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!