Background: Some porous materials have been developed to enhance biologic fusion of the implants to bone in spine fusion surgeries. However, there are several inherent limitations. In this study, a novel biomedical porous tantalum was applied to in vitro and in vivo experiments to test its biocompatibility and osteocompatibility.
Methods: Bone marrow-derived mesenchymal stem cells (BMSCs) were cultured on porous tantalum implant. Scanning electron microscope (SEM) and Cell Counting Kit-8 assay were used to evaluate the cell toxicity and biocompatibility. Twenty-four rabbits were performed discectomy only (control group), discectomy with autologous bone implanted (autograft group), and discectomy with porous tantalum implanted (tantalum group) at 3 levels: L3-L4, L4-L5, and L5-L6 in random order. All the 24 rabbits were randomly sacrificed at the different post-operative times (2, 4, 6, and 12 months; n = 6 at each time point). Histologic examination and micro-computed tomography scans were done to evaluate the fusion process. Comparison of fusion index scores between groups was analyzed using one-way analysis of variance. Other comparisons of numerical variables between groups were made by Student t test.
Results: All rabbits survived and recovered without any symptoms of nerve injury. Radiographic fusion index scores at 12 months post-operatively between autograft and tantalum groups showed no significant difference (2.89 ± 0.32 vs. 2.83 ± 0.38, F = 244.60, P = 0.709). Cell Counting Kit-8 assay showed no significant difference of absorbance values between the leaching liquor group and control group (1.25 ± 0.06 vs. 1.23 ± 0.04, t = -0.644, P = 0.545), which indicated the BMSC proliferation without toxicity. SEM images showed that these cells had irregular shapes with long spindles adhered to the surface of tantalum implant. No implant degradation, wear debris, or osteolysis was observed. Histologic results showed solid fusion in the porous tantalum and autologous bone implanted intervertebral spaces.
Conclusion: This novel porous tantalum implant showed a good biocompatibility and osteocompatibility, which could be a valid biomaterial for interbody fusion cages.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6629310 | PMC |
http://dx.doi.org/10.1097/CM9.0000000000000030 | DOI Listing |
J Orthop Surg Res
December 2024
Center for Joint Surgery, Southwest Hospital, Army Medical University, Gaotanyan Street, Shapingba District, Chongqing, 400038, China.
Purpose: This study aims to investigate the suitable surgical strategies for applying TaBw01 porous tantalum rod across different stages of osteonecrosis of the femoral head (ONFH).
Methods: TaBw01 tantalum rods were fabricated using type FTaY-1 tantalum powder via the foam impregnation-sintering method. Mechanical testing with the Instron 8801 universal testing machine and finite element analysis (FEA) assessed single tantalum rod implantation and impaction bone grafting combined with rod implantation.
Langmuir
December 2024
Key Laboratory of Soft Chemistry and Functional Materials of Education Ministry, Nanjing University of Science and Technology, Nanjing 210094, China.
Traditional anodization was generally conducted in aqueous or water-containing solutions at room temperature or even lower temperatures. The two best known examples of the application of traditional anodization in the fabrication of nanostructured oxides are porous anodic alumina and titania nanotube films. In 1998, Melody et al.
View Article and Find Full Text PDFZhongguo Gu Shang
November 2024
Department of Joint Surgery, the 940th Hospital of PLA Joint Logistics Support Force, Lanzhou 730050, Gansu, China.
Objective: To explore the surgical technique and clinical outcomes of biological total hip arthroplasty(THA) combined with impacting bone grafting for the treatment of moderate to severe acetabular invagination secondary to rheumatoid arthritis(RA).
Methods: Total of 20 patients(28 hips) with RA secondary to acetabular invagination were treated with THA of bioprosthesis combined with autogenous bone grafting from January 2012 to October 2020, including 5 males(8 hips) and 15 females(20 hips) with an average age of (55.10±4.
BMC Musculoskelet Disord
November 2024
Center for Sports Medicine, Southwest Hospital, Third Military Medical University, No. 30 Gaotanyan Street, Shapingba District, Chongqing, 400036, China.
Purpose: The conversion of knee arthrodesis to total knee arthroplasty (TKA) is a challenging procedure. This article aims to report a case of fusion knee with patellar absence who was converted to TKA and has achieved good results.
Methods: The patient, a 23 years old Tibetan Buddhist monk, sustained a left knee joint injury at the age of 12 due to a car accident, leading to subsequent knee arthrodesis at 18 years old as a result of recurrent severe infections.
J Arthroplasty
November 2024
Nottingham Elective Orthopaedic Services, Nottingham University Hospitals, Nottingham, United Kingdom; University of Nottingham, Nottingham, United Kingdom.
Background: Trabecular metal is being increasingly used in primary total hip arthroplasty (THA). This study compared medium-term (< 15 years) outcomes of fiber mesh titanium and trabecular metal acetabular components.
Methods: This study included 6,563 patients who underwent primary THA with either fiber mesh titanium or trabecular metal-backed acetabular components.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!