Objective: Often the assessment of mastoidectomy performance requires time-consuming manual rating. Virtual reality (VR) simulators offer potentially useful automated assessment and feedback but should be supported by validity evidence. We aimed to investigate simulator metrics for automated assessment based on the expert performance approach, comparison with an established assessment tool, and the consequences of standard setting.

Methods: The performances of 11 experienced otosurgeons and 37 otorhinolaryngology residents. Participants performed three mastoidectomies in the Visible Ear Simulator. Nine residents contributed additional data on repeated practice in the simulator. One hundred and twenty-nine different performance metrics were collected by the simulator and final-product files were saved. These final products were analyzed using a modified Welling Scale by two blinded raters.

Results: Seventeen metrics could discriminate between resident and experienced surgeons' performances. These metrics mainly expressed various aspects of efficiency: Experts demonstrated more goal-directed behavior and less hesitancy, used less time, and selected large and sharp burrs more often. The combined metrics-based score (MBS) demonstrated significant discriminative ability between experienced surgeons and residents with a mean difference of 16.4% (95% confidence interval [12.6-20.2], P << 0.001). A pass/fail score of 83.6% was established. The MBS correlated poorly with the final-product score but excellently with the final-product score per time.

Conclusion: The MBS mainly reflected efficiency components of the mastoidectomy procedure, and although it could have some uses in self-directed training, it fails to measure and encourage safe routines. Supplemental approaches and feedback are therefore required in VR simulation training of mastoidectomy.

Level Of Evidence: 2b Laryngoscope, 129:2170-2177, 2019.

Download full-text PDF

Source
http://dx.doi.org/10.1002/lary.27798DOI Listing

Publication Analysis

Top Keywords

automated assessment
12
simulator metrics
8
metrics automated
8
assessment mastoidectomy
8
mastoidectomy performance
8
simulator
5
metrics
5
assessment
5
expert sampling
4
sampling simulator
4

Similar Publications

To assess the choroidal vessels in healthy eyes using a novel three-dimensional (3D) deep learning approach. In this cross-sectional retrospective study, swept-source OCT 6 × 6 mm scans on Plex Elite 9000 device were obtained. Automated segmentation of the choroidal layer was achieved using a deep-learning ResUNet model along with a volumetric smoothing approach.

View Article and Find Full Text PDF

Respiratory support strategies in neonatal transport in the UK and Ireland.

Eur J Pediatr

January 2025

Department of Women and Children's Health, School of Life Course Sciences, Faculty of Life Sciences and Medicine, King's College London, Denmark Hill, London, UK.

Unlabelled: Infants requiring interhospital transfer for a higher level of care in the neonatal period are at increased risk of adverse outcomes. Optimising respiratory management is an important priority. The aim of this survey was to investigate current respiratory support strategies in neonatal transport and identify opportunities for the optimisation of clinical care and future research.

View Article and Find Full Text PDF

Background: Cardiovascular diseases such as coronary artery disease (CAD) have a high prevalence of psychiatric comorbidities, that may impact clinically relevant outcomes (e.g., cognitive impairment and executive dysfunction).

View Article and Find Full Text PDF

The advancements in cardiovascular imaging over the past two decades have been significant. The miniaturization of ultrasound devices has greatly contributed to their widespread adoption in operating rooms and intensive care units. The integration of AI-enabled tools has further transformed the field by simplifying echocardiographic evaluations and enhancing the reproducibility of hemodynamic measurements, even for less experienced operators.

View Article and Find Full Text PDF

Background: Specific pelvic bone dimensions have been identified as predictors of total mesorectal excision (TME) difficulty and outcomes. However, manual measurement of these dimensions (pelvimetry) is labor intensive and thus, anatomic criteria are not included in the pre-operative difficulty assessment. In this work, we propose an automated workflow for pelvimetry based on pre-operative magnetic resonance imaging (MRI) volumes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!