Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6522394PMC
http://dx.doi.org/10.2169/internalmedicine.1037-18DOI Listing

Publication Analysis

Top Keywords

obturator artery
4
artery pseudoaneurysm
4
obturator
1
pseudoaneurysm
1

Similar Publications

Background: Local relapse has not been eradicated even in the era of total mesorectum excision. Although various approaches have been attempted, R0 resection remains the only potentially curative treatment. PATIENT AND METHODS: A 45-year-old woman with a history of laparoscopic abdominoperineal resection was diagnosed with pelvic recurrence 7 months ago.

View Article and Find Full Text PDF

Unveiling the uncommon: hypoplasia of external iliac artery-a case report and literature review.

J Cardiothorac Surg

January 2025

Department of Cardiovascular Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, Hebei, 050000, P. R. China.

The absence or dysplasia of the iliac artery(IA) is an exceedingly rare condition, with limited cases documented in the literature. In this report, we present a case of hypoplasia of the right external iliac artery (EIA) in a 69-year-old male patient. The patient presented with right lower abdominal pain attributed to an aneurysm of the right internal iliac artery (IIA), yet notably, there was no evidence of lower limb ischemia at the time of consultation.

View Article and Find Full Text PDF

A Misplaced S2 Alar-Iliac Screw Causing L5 Spinal Nerve Injury: A Report of a Rare Case.

Cureus

November 2024

Orthopaedic Surgery and Sports Medicine, Tsukuba University Hospital Mito Clinical Education and Training Center, Mito Kyodo General Hospital, Mito, JPN.

Although neurovascular structures, including the superior gluteal artery, sciatic nerve, obturator nerve, internal iliac vein and artery, and lumbosacral plexus, are at risk when S2 alar-iliac (S2AI) screws are used, no cases of nerve injuries have been reported. An 84-year-old man was referred to our institute with persistent left sciatica for seven months after undergoing salvage surgery using S2AI screws for deep surgical site infection from a previous posterior interbody fusion surgery at L5-S1. Based on the radiographic and diagnostic selective nerve root block findings, a diagnosis of left L5 radiculopathy was suspected due to the left S2AI screw being caudally misplaced and severely protruding into the pelvic cavity.

View Article and Find Full Text PDF

The Genitofemoral Nerve Is the Structure Closest to the Tendon Footprint and Is Most at Risk for Iatrogenic Injury During Proximal Adductor Longus Repair: A Cadaveric Anatomy Study.

Arthrosc Sports Med Rehabil

October 2024

Section of Young Adult Hip Surgery, Division of Sports Medicine, Department of Orthopedic Surgery, Rush Medical College of Rush University, Rush University Medical Center, Chicago, Illinois, U.S.A.

Purpose: To identify structures at risk during proximal adductor longus repair and to report observed distances between these structures and the adductor longus (AL) footprint.

Methods: Eight hemipelves from fresh cadaver whole-body specimens were dissected using a previously established surgical approach. The tendinous attachment of the AL was scored into the underlying bone and the footprint size was measured in millimeters.

View Article and Find Full Text PDF

This case report describes the approach and use of an ultrasound-guided pudendal nerve block in dogs. The technique was first performed in the cadaver of a 14 kg male castrated Miniature Australian Shepherd dog. The ultrasound probe was placed in transverse orientation on midline between the anus and ischiatic arch.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!