A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Machine learning combined with non-targeted LC-HRMS analysis for a risk warning system of chemical hazards in drinking water: A proof of concept. | LitMetric

Machine learning combined with non-targeted LC-HRMS analysis for a risk warning system of chemical hazards in drinking water: A proof of concept.

Talanta

Norwegian Institute for Water Research (NIVA), Gaustadalléen 21, 0349 Oslo, Norway; Queensland Alliance for Environmental Health Science (QAEHS), University of Queensland, 20 Cornwall Street, Woolloongabba, QLD 4012, Australia.

Published: April 2019

Guaranteeing clean drinking water to the global population is becoming more challenging, because of the cases of water scarcity across the globe, growing population, and increased chemical footprint of this population. Existing targeted strategies for hazard monitoring in drinking water are not adequate to handle such diverse and multidimensional stressors. In the current study, we have developed, validated, and tested a machine learning algorithm based on the data produced via non-targeted liquid chromatography coupled with high resolution mass spectrometry (LC-HRMS) for the identification of potential chemical hazards in drinking water. The machine learning algorithm consisted of a composite statistical model including an unsupervised component (i.e. principal component analysis PCA) and a supervised one (i.e. partial least square discrimination analysis PLS-DA). This model was trained using a training set of 20 drinking water samples previously tested via conventional suspect screening. The developed model was validated using a validation set of 20 drinking water samples of which 4 were spiked with 15 labeled standards at four different concentration levels. The model successfully detected all of the added analytes in the four spiked samples without producing any cases of false detection. The same validation set was processed via conventional trend analysis in order to cross validate the composite model. The results of cross validation showed that even though the conventional trend analysis approach produced a false positive detection rate of ≤5% the composite model outperformed that approach by producing zero cases of false detection. Additionally, the validated model went through an additional test with 42 extra drinking water samples from the same source for an unbiased examination of the model. Finally, the potentials and limitations of this approach were further discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2018.11.039DOI Listing

Publication Analysis

Top Keywords

drinking water
28
machine learning
12
water samples
12
chemical hazards
8
hazards drinking
8
water
8
learning algorithm
8
model
8
set drinking
8
validation set
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!