Male rhesus macaques were subjected to partial-body irradiation at 10, 11, or 12 Gy with 5% bone marrow protection. Animals were euthanized when dictated by prospectively determined clinical parameters or at approximately 180 d following irradiation. Histological sections of jejunum, colon, and mesenteric lymph node were stained with hematoxylin and eosin as well as a battery of histochemical and immunohistochemical stains. The immediate postirradiation histopathological alterations in the jejunum and colon were based primarily on injury to rapidly proliferating crypt epithelial cells, though there was evidence of additional radiation-induced fibrogenic responses. There was substantial resolution of the radiation-related mucosal injury through the observation period, but microscopically visible defects in mucosal structure persisted to the end of the observation period. In the later stages of the observation period, the jejunum and colon had overt fibrosis that was most commonly located in the submucosa and serosa, with less microscopically discernible involvement of the mucosa. Mesenteric lymph nodes had an immediate postirradiation reduction in cellularity due to the known effects of irradiation on lymphoid cell populations. In later stages of the observation period the lymph nodes also developed fibrotic changes, possibly related to transmigration of immunomodulatory cells and/or signaling molecules from the radiation-damaged intestine.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6362996 | PMC |
http://dx.doi.org/10.1097/HP.0000000000000932 | DOI Listing |
BMC Public Health
January 2025
Department of Women's and Children's Health, Karolinska Institutet, Tomtebodavägen 18A, Stockholm, Solna, 171 77, Sweden.
Background: Globally, the quality of maternal and newborn care remains inadequate, as seen through indicators like perineal injuries and low Apgar scores. While midwifery practices have the potential to improve care quality and health outcomes, there is a lack of evidence on how midwife-led initiatives, particularly those aimed at improving the use of dynamic birth positions, intrapartum support, and perineal protection, affect these outcomes.
Objective: To explore how the use of dynamic birth positions, intrapartum support, and perineal protection impact the incidence of perineal injuries and the 5-min Apgar score within the context of a midwife-led quality improvement intervention.
BMC Anesthesiol
January 2025
Department of General Medicine, Shaoxing Central Hospital, Shaoxing, Zhejiang, 312030, China.
This study explores the association between serum chloride concentrations and all-cause mortality among patients in the Surgical Intensive Care Unit (SICU). Employing a retrospective cohort design, the study utilized data extracted from the Medical Information Mart for Intensive Care IV (MIMIC-IV) database, specifically focusing on individuals admitted to the surgical/trauma ICUs. This dataset encompassed demographic profiles, laboratory findings, historical medical data, vital statistics, and variables pertinent to prognosis.
View Article and Find Full Text PDFSurg Endosc
January 2025
Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Background And Aims: Self-expandable metal stents (SEMS) are effective in alleviating malignant colorectal obstruction. However, bowel perforation following SEMS placement remains a significant concern, as it can adversely affect oncological outcomes. This study aimed to evaluate the recurrence and overall survival rates associated with SEMS-related bowel perforations.
View Article and Find Full Text PDFCardiovasc Eng Technol
January 2025
Transonic Systems Inc., 34 Dutch Mill Road, Ithaca, New York, 14850, USA.
Purpose: Over time, transit time flow measurement (TTFM) has proven itself as a simple and effective tool for intra-operative evaluation of coronary artery bypass grafts (CABGs). However, metrics used to screen for possible technical error show considerable spread, preventing the definition of sharp cut-off values to distinguish between patent, questionable, and failed grafts. The simulation study presented in this paper aims to quantify this uncertainty for commonly used patency metrics, and to identify the most important physiological parameters influencing it.
View Article and Find Full Text PDFEnviron Monit Assess
January 2025
Institut de Recherche Robert-Sauvé en Santé Et en Sécurité du Travail (IRSST), Montréal, Québec, Canada.
In recyclable waste management facilities, several contaminants, mainly bioaerosols and microorganisms, can be released and cause potential adverse health effects. Given that microbial volatile organic compounds (mVOCs) are metabolites developed by molds and since they can be considered as potential biomarkers of mold exposure, their concentrations in ambient air were monitored at a recyclable waste sorting plant (WSP) and a university campus (UC) serving as control environment for comparison. A recently developed analytical method was used for the detection of 21 selected mVOCs in real conditions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!