Background: Hyaluronic acid (HA) fillers have increased in popularity. Although complications are rare, knowledge regarding their prevention and management are crucial. The utility of preinjection aspiration has become controversial.

Objective: Our study investigated the utility of preinjection aspiration as a safety checkpoint for HA fillers through comparison of physiochemical and rheological properties in an in vitro model.

Materials And Methods: Whole blood was drawn from vacutainers using syringes containing 10 commonly used HA fillers. Each HA filler was examined with the plunger pulled back at volumes of 0.2 and 0.5 cc. The time required to visualize a flash was recorded. Data were compared using physiochemical and rheological properties, pullback volumes, and needle gauges.

Results: Using a multivariable regression model, HA concentration, elastic modulus (G'), viscous modulus (G″), and complex modulus (G*) had significant relationships with time to flash, whereas needle gauge and pullback volume did not. However, when comparing pullback volume using an appropriate paired analysis, 0.5 cc pullback volume had a significantly decreased mean time to flash than 0.2 cc.

Conclusion: Preinjection aspiration may have utility as a safety checkpoint for HA fillers. Practitioners may have to adjust pullback volume and waiting time to visualize the flash based on physiochemical and rheological properties.

Download full-text PDF

Source
http://dx.doi.org/10.1097/DSS.0000000000001767DOI Listing

Publication Analysis

Top Keywords

preinjection aspiration
16
pullback volume
16
safety checkpoint
12
physiochemical rheological
12
rheological properties
12
utility preinjection
8
checkpoint fillers
8
visualize flash
8
time flash
8
fillers
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!