Evaluation of a Piezo-Actuated Sensor for Monitoring Elastic Variations of Its Support with Impedance-Based Measurements.

Sensors (Basel)

Computational and Experimental Mechanics Laboratory, Universidad Autónoma de Manizales, Antigua Estación del Ferrocarril, edificio fundadores, C.P. 170001 Manizales-Caldas, Colombia.

Published: January 2019

This study exposes the assessment of a piezo-actuated sensor for monitoring elastic variations (change in Young's modulus) of a host structure in which it is attached. The host structure is monitored through a coupling interface connected to the piezo-actuated device. Two coupling interfaces were considered (an aluminum cone and a human tooth) for the experimental tests. Three different materials (aluminum, bronze and steel) were prepared to emulate the elastic changes in the support, keeping the geometry as a fixed parameter. The piezo device was characterized from velocity frequency response functions in pursuance to understand how vibration modes stimulate the electrical resistance through electrical resonance peaks of the sensor. An impedance-based analysis (1⁻20 kHz) was performed to correlate elastic variations with indexes based on root mean square deviation (RMSD) for two observation windows (9.3 to 9.7 kHz and 11.1 to 11.5 kHz). Results show that imposed elastic variations were detected and quantified with the electrical resistance measurements. Moreover, it was demonstrated that the sensitivity of the device was influenced by the type of coupling interface since the cone was more sensitive than the tooth in both observation windows. As a final consideration, results suggest that bio-structures (fruits and bone, among others) could be studied since these can modify naturally its elastic properties.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6339132PMC
http://dx.doi.org/10.3390/s19010184DOI Listing

Publication Analysis

Top Keywords

elastic variations
16
piezo-actuated sensor
8
sensor monitoring
8
monitoring elastic
8
host structure
8
coupling interface
8
electrical resistance
8
observation windows
8
elastic
6
evaluation piezo-actuated
4

Similar Publications

As the face ages, the skin, fat, muscle, and fascia descend, and the underlying bone, cartilage, and teeth may lose mass. Oculofacial aging is a multifactorial process that is influenced by genetic, environmental, and lifestyle factors. This review summarizes the patterns of oculofacial aging that are observed across populations, including variations in periorbital hollowing, eyelid ptosis, and skin elasticity.

View Article and Find Full Text PDF

Precision of Fungal Resistance Test Method for Cereal Husk-Reinforced Composite Construction Profiles Considering Mycelium Removal Techniques.

Materials (Basel)

January 2025

Construction Materials Engineering Department, Instytut Techniki Budowlanej, 00-611 Warsaw, Poland.

Many test methods used in the assessment of construction products are characterised by poor precision, which is reflected in the discrepancies of results obtained by different laboratories. The test procedure for fungal resistance of natural particle-reinforced composite construction profiles has not been fully specified, which may lead to such discrepancies and erroneous utility assessment. In this study, the precision of the method and the influence of the mycelium removal on the fungal resistance were assessed based on the flexural strength and modulus of elasticity test results obtained for millet- and oat husk-reinforced PVC composites exposed to .

View Article and Find Full Text PDF

This study evaluated the effect of oral cavity environmental factors on the friction and wear of materials used in 3D-printed orthodontic devices. Commercial materials GR-10 (Pro3Dure) and NextDent SG (NextDent) were examined, with samples produced using ASIGA UV MAX and Phrozen Shuffle Lite 3D printers. Our tests included measurements of hardness, stiffness, elastic modulus, cyclic loading, scratch resistance, and tribological assessments in oscillatory motion.

View Article and Find Full Text PDF

Background/objectives: This study pioneers the application of the ViPLUS module, utilizing plane-wave ultrasound to measure breast tissue viscosity and elasticity. The primary goal was to establish normal reference values for viscosity in healthy women. Secondary objectives included exploring correlations between breast tissue viscosity and breast density categories, hormonal influences, and menstrual cycle phases.

View Article and Find Full Text PDF

The local pulse wave velocity (PWV) from large elastic arteries and its pressure-dependent changes within a cardiac cycle are potential biomarkers for cardiovascular risk stratification. However, pulse wave reflections can impair the accuracy of local PWV measurements. We propose a method to measure pressure-dependent variations in local PWV while minimizing the influence of pulse wave reflections.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!