Purpose: This paper presents a calibration curve for prematurely condensed chromosome rings (PCC-ring) which are scarce in cytogenetic dosimetry; here we analyzed the behavior of the PCC-ring frequency and PCC index after gamma irradiation in the dose interval from 0 to 20 Gy.
Materials And Methods: PCC-rings were induced in lymphocytes with Calyculin A. A total of 5788 PCC cells in G1, G2/M, and M/A stages were analyzed.
Results: The best fitting curve between the frequency of PCC ring (Y) and the Dose (D) was obtained with the equation Y = (0.0308 ± 0.0012) D. The distribution of rings by cell followed a Poisson distribution. The PCC index was correlated with radiation dose and decreased in a dose-dependent manner.
Conclusion: This PCC-ring dose-effect curve can be used in case of high dose accidental overexposure to gamma radiation, allowing a dose assessment in a reliable way in most of the simulated irradiation analyzed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/09553002.2019.1566677 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!