A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

With or Without Internal Standard in HPLC Bioanalysis. A Case Study. | LitMetric

The mandatory strategy of using internal standard in HPLC is still controversial. Despite that the introduction of internal standard methodology in the early stage of development of HPLC technology was used to improve method accuracy and precision, there are still practical situations in which a simple external standard quantification is adequate. The aim of the study is to compare the determination of meloxicam (MXC) in human plasma by HPLC with or without using an internal standard according to some key points related to the reason of introducing the internal standardization such as the reducing of sample preparation errors or variability for low injection volumes. The HPLC analysis was performed on reversed phase with UV detection after protein precipitation. Piroxicam (PXC) was used as an internal standard. The two methods are compared in terms of accuracy and precision over the same concentration range. The stability of the analyte has been proved. According to the results, the quantitative determination of MXC in human plasma after simple protein precipitation by using PXC as an internal standard does not bring any significant improvement of accuracy and precision of the experimental measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmy106DOI Listing

Publication Analysis

Top Keywords

internal standard
24
accuracy precision
12
standard hplc
8
mxc human
8
human plasma
8
protein precipitation
8
pxc internal
8
internal
7
standard
6
hplc
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!