Component positioning and ceramic damage in cementless ceramic-on-ceramic total hip arthroplasty.

J Orthop Sci

Ortopedia-Traumatologia e Chirurgia Protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, Bologna, 40136, Italy.

Published: July 2019

Background: In ceramic-on-ceramic (CoC) total hip arthroplasty (THA), component positioning demonstrated to influence the bearing damage: however the connection between angles and clinical outcomes at long-term follow-ups is currently lacking. Aims of this study were: the computer tomography (CT) assessment of component positioning in CoC THAs; the correlation analysis between positioning and ceramic damage; the identification of safe zones.

Methods: 91 consecutive post-operative CT scans including two types of CoC implants, with a mean follow-up of 12 ± 4.4 years, were evaluated. III generation (74.2%) and IV generation (25.8%) CoC surfaces were included. The angle measurements (cup abduction, anteversion, cup tilt, stem antetorsion, sacral slope) were automated using a CT-based software. The combined anteversion was assessed as well as the cup-neck position at -15°, 0°, 45° and 90° of flexion. Ceramic damage was diagnosed using synovial fluid analyses and radiological criteria.

Results: 63.7% of THAs was inside the cup abduction target 30°-45° and 68.1% was inside the cup anteversion target 5°-25°. 19 patients (20.9%) showed signs of ceramic damage. High cup abduction and high cup-neck 45° minimum angle (which stood for high abduction and extreme combined version) significantly correlated with ceramic damage. No demographical features apart III generation ceramic bearings influenced the results. No safe zones could be detected.

Conclusions: In CoC THA, no safe zones can be described. However it is important to avoid cup inclination over 45° and a combination of steep cup and extreme combined version.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jos.2018.12.011DOI Listing

Publication Analysis

Top Keywords

ceramic damage
20
component positioning
12
cup abduction
12
positioning ceramic
8
total hip
8
hip arthroplasty
8
iii generation
8
inside cup
8
extreme combined
8
combined version
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!