In this study, a novel two dimensional liquid chromatography - mass spectrometry (2D-LC-MS) method with use of a weak anion exchange column between the 1st DLC RP column and the 2nd DLC RP column (RP1-WAX-RP2) was developed and applied to identify drug impurities from MS incompatible mobile phases containing sodium 1-octanesulfonate and non-volatile buffer. The 1st DLC conditions follow exactly the original standard HPLC method recorded in Chinese Pharmacopeia (ChP), European Pharmacopeia (EP) or US Pharmacopeia (USP). An impurity fraction was collected with a built-in sample loop (100 μL) and transferred to the WAX column where 1-octanesulfonate and phosphate were trapped and removed. While, the impurity and other cations were eluted to the 2nd D column (RP2) for separation and identification by connected IT-TOF MS. Methods were programmed and applied to identify impurities in two generic drugs, sulpiride (hydrophilic drug with logP 0.57) and dobutamine (hydrophobic drug with logP 3.6). The results indicate that the methods based on RP1-WAX-RP2 column configuration offer a feasible solution for direct impurity identification in generic drug product or API without needs of off-line desalting from the MS incompatible mobile phases containing ion-pairing reagent and non-volatile buffer.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2018.10.031DOI Listing

Publication Analysis

Top Keywords

mobile phases
12
liquid chromatography
8
chromatography mass
8
mass spectrometry
8
impurity identification
8
ion-pairing reagent
8
1st dlc
8
dlc column
8
applied identify
8
incompatible mobile
8

Similar Publications

Development and validation of a sensitive LC-MS/MS assay for determination of upadacitinib in human plasma and its application in patients with inflammatory bowel disease.

J Pharmacol Toxicol Methods

January 2025

Department of Pharmacy, the First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China; Department of Gastroenterology, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China. Electronic address:

Background: Upadacitinib is a selective Janus kinase (JAK) 1 inhibitor approved by the Food and Drug Administration for the treatment of moderate-to-severe inflammatory bowel disease (IBD). We aimed to establish and validate a method for determining Upadacitinib in patients with IBD by liquid chromatography-tandem mass spectrometry (LC-MS/MS) method.

Methods: The mobile phase was 0.

View Article and Find Full Text PDF

A randomized control trial to compare Quiet Eye training efficacy to traditional technical training with undergraduate student nurses' peripheral intravenous cannulation performance: a protocol.

Br J Nurs

January 2025

Department of Psychology, Faculty of Arts, University of Calgary, Alberta, Canada; Community Health Sciences, Faculty of Medicine, University of Calgary, Alberta, Canada; Ward of the 21st Century, Cumming School of Medicine, University of Calgary, Alberta, Canada.

Introduction: Peripheral intravenous cannulation (PIVC) is a common and complex procedure with low first-attempt success rates, causing patient suffering and increased healthcare costs. Quiet Eye (QE) training, a gaze-focused approach, has shown promise in improving procedural PIVC skills. We will examine the effectiveness of traditional technical training (TT) and QE training (QET) on student nurse PIVC performance.

View Article and Find Full Text PDF

Background: A mobile cognition scale for community screening in cognitive impairment with rigorous validation is in paucity. We aimed to develop a digital scale that overcame low education for community screening for mild cognitive impairment (MCI) due to Alzheimer's disease (AD) and AD.

Methods: A mobile cognitive self-assessment scale (CogSAS) was designed through the Delphi process, which is feasible for the older population with low education.

View Article and Find Full Text PDF

(L.) Jacq. has anti-inflammatory, analgesic, haemostatic and antioxidant effects, but its pharmacological components are still unclear.

View Article and Find Full Text PDF

A novel method for multi-matrix arsenic speciation analysis by anion-exchange HPLC-ICP-MS in the framework of the third (French) total diet study.

Anal Bioanal Chem

January 2025

Laboratory for Food Safety, French Agency for Food, Environmental and Occupational Health & Safety (ANSES), Université Paris-Est, 94700, Maisons-Alfort, France.

This study presents the development and validation of a precise analytical method for the speciation analysis of arsenic (As) compounds, including inorganic species [As(III) and As(V)] and organic species such as monomethylarsonic acid (MMA) and dimethylarsinic acid (DMA). The method employs anion-exchange high-performance liquid chromatography (AE HPLC) coupled with inductively coupled plasma-mass spectrometry (ICP-MS). To optimize the sample preparation process, microwave-assisted extraction (MAE) and heat-assisted extraction (HAE) techniques were evaluated and compared.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!