Estrogens determination exploiting a SIA-LOV system prior in-port derivatization-large volume injection-programmable temperature vaporization-gas chromatography.

Talanta

Sciware Systems, S.L. Spin-off from the University of the Balearic Islands, C/ Pi 37, 07193, Illes Balears, Spain; Department of Chemistry, Faculty of Sciences, University of the Balearic Islands, Carretera de Valldemossa km 7.5, E-07122 Palma de Mallorca, Illes Balears, Spain. Electronic address:

Published: March 2019

AI Article Synopsis

  • The study introduces a method for cleaning, concentrating, and measuring four common estrogens in seawater samples using a fully automated system called SIA-LOV.
  • Different resins and solvents were tested, ultimately selecting C18 resin with acetonitrile, which provided optimal results for the extraction process.
  • The method allows for up to 50 consecutive analyses with the same extraction column, and includes an unattended derivatization step prior to quantification using advanced gas chromatography techniques.

Article Abstract

In this work, we present a method for the clean-up, preconcentration and quantification of the four most widely found estrogens (estrone E1, estradiol E2, estriol E3 and ethynyl estradiol EE2) in seawater samples. A sequential injection analysis-lab on valve system (SIA-LOV) has been developed to perform the microsolid phase extraction (µSPE) of the analytes in a fully automated way. After testing different resins and solvents, C18 resin with acetonitrile (ACN) as eluent have been chosen as they provided the best results. Several parameters affecting the extraction have been studied and optimized. Besides, extraction column lifetime has also been checked as it is indicative of the number of consecutive analysis that the column is able to perform before replacing it. Results showed that the same column can be used up to 50 times. Then, the derivatization of the extracts has been performed unattended by exploiting an in-port derivatization of the analytes with N-methyltrimethylsilyltrifluoroacetamide (BSTFA) prior their quantification using large volume injection with programmable temperature vaporization gas chromatography (LVI-PTV-GC-MS).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2018.10.105DOI Listing

Publication Analysis

Top Keywords

estrogens determination
4
determination exploiting
4
exploiting sia-lov
4
sia-lov system
4
system prior
4
prior in-port
4
in-port derivatization-large
4
derivatization-large volume
4
volume injection-programmable
4
injection-programmable temperature
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!