A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sensitive determination of silicon contents in low-alloy steels using micro laser-induced breakdown spectroscopy assisted with laser-induced fluorescence. | LitMetric

Silicon element plays an important role in strength and hardness improvement in steels, but is harmful for ductility, tenacity, and anti-corrosion. Therefore, silicon content should be fast determined in steel manufacture to keep silicon in moderation. In this work, micro laser-induced breakdown spectroscopy assisted with laser-induced fluorescence (μLIBS-LIF) was proposed to sensitively determine silicon in low-alloy steels. The mechanism and excitation selection of laser-induced silicon atomic fluorescence in laser-induced plasma were discussed. Under 10 µm laser-ablated scatters, the results showed that μLIBS-LIF had analytical performance with R of 0.9998, LoD of 2.8 μg g, and RMSECV of 63 μg g, significantly better than μLIBS under their respective optimal conditions. The analytical sensitivity in μLIBS-LIF was even better than macro LIBS in others' works. As our best knowledge, the silicon LoD in LIBS technique was improved to better than 10 μg g in steel matrix for the first time. This work demonstrates μLIBS-LIF as a capable and potential approach for fast determining silicon element in steel industries.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2018.10.069DOI Listing

Publication Analysis

Top Keywords

silicon
8
low-alloy steels
8
micro laser-induced
8
laser-induced breakdown
8
breakdown spectroscopy
8
spectroscopy assisted
8
assisted laser-induced
8
laser-induced fluorescence
8
silicon element
8
laser-induced
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!