Computational models of anthropomorphic test devices (ATDs) can be used in crash simulations to quantify the injury risks to occupants in both a cost-effective and time-sensitive manner. The purpose of this study was to validate the performance of a 50 percentile THOR finite element (FE) model against a physical THOR ATD in 11 unique loading scenarios. Physical tests used for validation were performed on a Horizontal Impact Accelerator (HIA) where the peak sled acceleration ranged from 8-20 G and the time to peak acceleration ranged from 40-110 ms. The directions of sled acceleration relative to the THOR model consisted of -GX (frontal impact), +GY (left-sided lateral impact), and +GZ (downward vertical impact) orientations. Simulation responses were compared to physical tests using the CORrelation and Analysis (CORA) method. Using a weighted method, the average response and standard error by direction was +GY (0.83±0.03), -GX (0.80±0.01), and +GZ (0.76±0.03). Qualitative and quantitative results demonstrated the FE model's kinetics and kinematics were sufficiently validated against its counterpart physical model in the tested loading directions.

Download full-text PDF

Source
http://dx.doi.org/10.4271/2018-22-0012DOI Listing

Publication Analysis

Top Keywords

finite element
8
percentile thor
8
anthropomorphic test
8
physical tests
8
sled acceleration
8
acceleration ranged
8
validation finite
4
element 50th
4
50th percentile
4
thor
4

Similar Publications

Finite model analysis of different anchorage sites for bone-supported facemask application in unilateral cleft lip and palate.

Am J Orthod Dentofacial Orthop

January 2025

Department of Orthodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey. Electronic address:

Introduction: The objective of this study was to evaluate the effects of the miniplate application sites in the maxilla and the applied force vector changes during skeletally supported facemask application in adolescent patients with unilateral cleft lip and palate (UCLP) using finite element model (FEM) analysis.

Methods: A FEM was obtained from a cone-beam computed tomography image of a 12-year-old female patient with UCLP. Miniplates were placed on 3 different sites of the maxilla; 500 g of advancement force was applied bilaterally, parallel (0°), and downward (-30°) to the occlusal plane.

View Article and Find Full Text PDF

Proximal femoral fractures are particularly common in older adults, and cases requiring conversion to total hip arthroplasty may arise because of treatment failure or osteoarthritis. Fractures around the distal screw removal holes can be problematic. This study aimed to analyze the relationship between stem length and femoral stress distribution to determine the optimal stem length.

View Article and Find Full Text PDF

In naval engineering, particular attention has been given to containerships, as these structures are constantly exposed to potential damage during service hours and since they are essential for large-scale transportation. To assess the structural integrity of these ships and to ensure the safety of the crew and the cargo being transported, it is essential to adopt structural health monitoring (SHM) strategies that enable real-time evaluations of a ship's status. To achieve this, this paper introduces an advancement in the field of smart sensing and SHM that improves ship monitoring and diagnostic capabilities.

View Article and Find Full Text PDF

The directivity of the quasi-static component (QSC) is quantitatively investigated for evaluating the orientation of a micro-crack buried in a thin solid plate using the numerical simulation method. Based on the bilinear stress-strain constitutive model, a three-dimensional (3D) finite element model (FEM) is built for investigating the nonlinear interaction between primary Lamb waves and the micro-crack. When the primary Lamb waves at A0 mode impinge on the micro-crack, under the modulation of the contact acoustic nonlinearity (CAN), the micro-crack itself will induce QSC.

View Article and Find Full Text PDF

This study focuses on the geotechnical evaluation of the foundation conditions of the Agrippa Monument at the Acropolis of Athens, aiming to propose interventions to improve stability and reduce associated risks. The assessment reveals highly uneven foundation conditions beneath the monument. A thorough collection of bibliographic references and geotechnical surveys was conducted, classifying geomaterials into engineering-geological units and evaluating critical parameters for geotechnical design.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!