Background: During passive mechanical ventilation, the driving pressure of the respiratory system is an important mediator of ventilator-induced lung injury. Monitoring of driving pressure during assisted ventilation, similar to controlled ventilation, could be a tool to identify patients at risk of ventilator-induced lung injury. The aim of this study was to describe driving pressure over time and to identify whether and when high driving pressure occurs in critically ill patients during assisted ventilation.

Methods: Sixty-two patients fulfilling criteria for assisted ventilation were prospectively studied. Patients were included when the treating physician selected proportional assist ventilation (PAV+), a mode that estimates respiratory system compliance. In these patients, continuous recordings of all ventilator parameters were obtained for up to 72 h. Driving pressure was calculated as tidal volume-to-respiratory system compliance ratio. The distribution of driving pressure and tidal volume values over time was examined, and periods of sustained high driving pressure (≥ 15 cmHO) and of stable compliance were identified and analyzed.

Results: The analysis included 3200 h of ventilation, consisting of 8.8 million samples. For most (95%) of the time, driving pressure was < 15 cmHO and tidal volume < 11 mL/kg (of ideal body weight). In most patients, high driving pressure was observed for short periods of time (median 2.5 min). Prolonged periods of high driving pressure were observed in five patients (8%). During the 661 periods of stable compliance, high driving pressure combined with a tidal volume ≥ 8 mL/kg was observed only in 11 cases (1.6%) pertaining to four patients. High driving pressure occurred almost exclusively when respiratory system compliance was low, and compliance above 30 mL/cmHO excluded the presence of high driving pressure with 90% sensitivity and specificity.

Conclusions: In critically ill patients fulfilling criteria for assisted ventilation, and ventilated in PAV+ mode, sustained high driving pressure occurred in a small, yet not negligible number of patients. The presence of sustained high driving pressure was not associated with high tidal volume, but occurred almost exclusively when compliance was below 30 mL/cmHO.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6314935PMC
http://dx.doi.org/10.1186/s13613-018-0477-4DOI Listing

Publication Analysis

Top Keywords

driving pressure
36
driving
9
proportional assist
8
assist ventilation
8
pressure
8
respiratory system
8
ventilator-induced lung
8
lung injury
8
assisted ventilation
8
high driving
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!