Transscleral LED illumination pen.

Biomed Eng Lett

3Ulm University of Applied Sciences, Albert-Einstein-Allee 55, 89081 Ulm, Germany.

Published: November 2017

Existing light sources for intraocular illumination are often bulky and expensive and pose a risk for the patient, because light guides are inserted in the eye through incisions and if the tip of these light guides get too close to the retina, the retina can be damaged photochemically within minutes or even seconds. Therefore a new, safe and simple device for intraocular illumination is developed and evaluated for its thermal and photochemical risks to the patient. It consists of a white LED which is integrated into a pen like holder. This device is pressed against the sclera by the physician who seeks for illumination during surgery or for diagnostic purposes. The LED light is transmitted through the sclera without the need for an incision. Considering the relevant standards, the device poses no harm to the patient, and in tests with the authors' own eyes a sufficient intraocular illumination is reached. The proposed device is quite simple but easy to handle and very gentle for the patient.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6208513PMC
http://dx.doi.org/10.1007/s13534-017-0039-yDOI Listing

Publication Analysis

Top Keywords

intraocular illumination
12
light guides
8
illumination
5
transscleral led
4
led illumination
4
illumination pen
4
pen existing
4
light
4
existing light
4
light sources
4

Similar Publications

A Comparative Analysis of the Effects of Misaligning Different Trifocal Intraocular Lenses.

J Clin Med

December 2024

The David J Apple Center for Vision Research, Department of Ophthalmology, Heidelberg University Eye Clinic, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.

This laboratory study aims to assess the effects of misaligning different trifocal intraocular lenses (IOLs) under varying spectral and corneal spherical aberration (SA) conditions. With an IOL metrology device under monochromatic and polychromatic conditions, the following models were studied: AT ELANA 841P, AT LISA Tri 839MP, FineVision HP POD F, Acrysof IQ PanOptix, and Tecnis Synergy ZFR00V. The SA was simulated using an aberration-free and average-SA cornea.

View Article and Find Full Text PDF

We report a rare case of a missed intracavernous internal carotid artery dissecting aneurysm occurring as a complication of the base of skull fracture with severe brain injury causing acute cavernous sinus syndrome with permanent vision loss. A 31-year-old Myanmar lady had an alleged motor vehicle accident and suffered severe traumatic brain injury with multiple intracranial bleeds, multiple facial bone and base of skull fractures, and limb fractures. At one week post-trauma, she had severe right eye proptosis with vision loss, ophthalmoplegia, chemosis, and high intraocular pressure.

View Article and Find Full Text PDF

This study characterizes a fluorescent -tdTomato neuronal reporter mouse line with strong labeling of axons throughout the optic nerve, of retinal ganglion cell (RGC) soma in the ganglion cell layer (GCL), and of RGC dendrites in the inner plexiform layer (IPL). The model facilitated assessment of RGC loss in models of degeneration and of RGC detection in mixed neural/glial cultures. The tdTomato signal showed strong overlap with >98% cells immunolabeled with RGC markers RBPMS or BRN3A, consistent with the ubiquitous presence of the vesicular glutamate transporter 2 (VGUT2, SLC17A6) in all RGC subtypes.

View Article and Find Full Text PDF

Potential guidelines for cataract surgery and rehabilitation in visually impaired patients: Literature analysis.

Aging Med (Milton)

December 2024

Department of Sense Organs, Faculty of Medicine and Odontology, Rare Retinal Diseases and Ocular Electrophysiology Centre, Umberto I Policlinic Sapienza University of Rome Rome Italy.

Cataracts can reduce the quality of vision in visually impaired patients who already have a visual impairment. The most common causes of low vision include age-related macular degeneration (AMD), high myopia (HM), diabetic retinopathy (DR), glaucoma (GL), and inherited degenerative ocular diseases. The surgery aims to improve their independence, quality of life, and ability to engage in daily, social, and work activities.

View Article and Find Full Text PDF

Purpose: Aqueous humor inflow rate, a key parameter influencing aqueous humor dynamics, is typically measured by fluorophotometry. Analyzing fluorophotometric data depends, inter alia, on the volume of aqueous humor in the anterior chamber but not the posterior chamber. Previous fluorophotometric studies of the aqueous inflow rate in mice have assumed the ratio of anterior:posterior volumes in mice to be similar to those in humans.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!