A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Geometrical characterization of the cavitation bubble clouds produced by a clinical shock wave device. | LitMetric

Geometrical characterization of the cavitation bubble clouds produced by a clinical shock wave device.

Biomed Eng Lett

1Department of Medicine, School of Medicine, Jeju National University, 102 Jejudaehakno, Jeju-Si, Jeju Special Self-Governing Province 63294 Republic of Korea.

Published: May 2017

This study was to optically visualize the cavitation bubbles produced by a clinical shock wave and to look into their geometric features of the resulting cavitation bubbles in relation to the driving shock wave field. A clinical shock wave therapeutic system was taken for shock wave production. The shock wave induced cavitation bubbles were captured by a professional camera under the illumination of a micro-pulse LED light. The light exposure was set to last for the whole life time of bubbles from formation to subsequent collapses. It was shown that the cavitation bubbles appeared mostly in the vicinity of the focus. The bubbles became more and larger as approaching to the focus. The cavitation bubbles formed jet streams which became enlarged (stronger) as the shock wave device output setting increased. The bubble cloud boundary was reasonably fitted to an elongated ellipsoid characteristically similar to the acoustic focal area. The bubble clouds were enlarged as the output setting increased. The geometric features of the cavitation bubbles characteristically similar to those of the focusing acoustic field have potential to provide the therapeutic focal information without time consuming hydrophone measurements of the shock wave field causing damages of the expensive sensor. The present study is limited to the static afterimages of the cavitation bubbles and investigation including the bubble dynamics is suggested to deliver the more realistic therapeutic area of the shock wave therapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6208467PMC
http://dx.doi.org/10.1007/s13534-017-0017-4DOI Listing

Publication Analysis

Top Keywords

shock wave
36
cavitation bubbles
28
clinical shock
12
shock
9
wave
9
bubbles
9
cavitation
8
bubble clouds
8
produced clinical
8
wave device
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!