A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of Cyclic Dislodging on the Retention of Two Attachment Systems for Implant-supported Overdentures: An In Vitro Study. | LitMetric

Purpose: The aim of this study was to compare and evaluate the retention of two new attachment systems used for implant-supported overdentures subjected to insertion-removal cycles.

Materials And Methods: Twenty custom-manufactured polyvinyl chloride models mimicking implant-retained over-dentureresin blocks were fabricated and divided into two groups (n = 10): group 1 ('Kerator' attachment) and group 2 ('EMI' attachment). Each model received two parallel implants (JD evolution®) 20 mm apart and was subjected to cyclic retention forces of 10, 100, 1000, 5000, 10000 and 14600 cycles using a universal testing machine in a 0.9% sodium chloride water solution at 22° C. Data were analyzed using one-way analysis of variance; the level of significance was set at a < 0.05.

Results: The 'Kerator' and 'EMI' attachment systems reported a significant decrease in retention (64 and 56.6% respectively) after 14600 insertion-removal cycles (p < 0.001). The 'EMI' attachment showed significant higher loss of retention than the 'Kerator' attachment all along the 14600 cycles (p < 0.05) except for cycles 100 and 5000 (p > 0.05).

Conclusion: Within the limitations of this in vitro study, both attachments reported satisfactory retentive values during the 14600 cycles, the 'Kerator' attachment showed better retention than the new 'EMI' attachment. The initial retentive force of both attachments has gradually decreased.

Clinical Significance: Both attachment systems evaluated in this study can be used in clinical practice for implant-supported overdentures.

Download full-text PDF

Source

Publication Analysis

Top Keywords

attachment systems
16
'emi' attachment
16
implant-supported overdentures
12
'kerator' attachment
12
14600 cycles
12
attachment
10
retention attachment
8
systems implant-supported
8
vitro study
8
retention
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!