Purpose: The aim of this study was to improve the geometric fidelity and spatial resolution of multi-b diffusion-weighted magnetic resonance imaging of the prostate.

Materials And Methods: An accelerated segmented diffusion imaging sequence was developed and evaluated in 25 patients undergoing multiparametric magnetic resonance imaging examinations of the prostate. A reduced field of view was acquired using an endorectal coil. The number of sampled diffusion weightings, or b-factors, was increased to allow estimation of tissue perfusion based on the intravoxel incoherent motion (IVIM) model. Apparent diffusion coefficients measured with the proposed segmented method were compared with those obtained with conventional single-shot echo-planar imaging (EPI).

Results: Compared with single-shot EPI, the segmented method resulted in faster acquisition with 2-fold improvement in spatial resolution and a greater than 3-fold improvement in geometric fidelity. Apparent diffusion coefficient values measured with the novel sequence demonstrated excellent agreement with those obtained from the conventional scan (R = 0.91 for bmax = 500 s/mm and R = 0.89 for bmax = 1400 s/mm). The IVIM perfusion fraction was 4.0% ± 2.7% for normal peripheral zone, 6.6% ± 3.6% for normal transition zone, and 4.4% ± 2.9% for suspected tumor lesions.

Conclusions: The proposed accelerated segmented prostate diffusion imaging sequence achieved improvements in both spatial resolution and geometric fidelity, along with concurrent quantification of IVIM perfusion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6402959PMC
http://dx.doi.org/10.1097/RLI.0000000000000536DOI Listing

Publication Analysis

Top Keywords

geometric fidelity
16
accelerated segmented
12
spatial resolution
12
magnetic resonance
8
resonance imaging
8
diffusion imaging
8
imaging sequence
8
apparent diffusion
8
segmented method
8
ivim perfusion
8

Similar Publications

Background: Diffusion-weighted (DW) turbo-spin-echo (TSE) imaging offers improved geometric fidelity compared to single-shot echo-planar-imaging (EPI). However, it suffers from low signal-to-noise ratio (SNR) and prolonged acquisition times, thereby restricting its applications in diagnosis and MRI-guided radiotherapy (MRgRT).

Purpose: To develop a joint k-b space reconstruction algorithm for concurrent reconstruction of DW-TSE images and the apparent diffusion coefficient (ADC) map with enhanced image quality and more accurate quantitative measurements.

View Article and Find Full Text PDF

Due to its inbuilt ability to release biocompatible materials encapsulating living cells in a predefined location, 3D bioprinting is a promising technique for regenerating patient-specific tissues and organs. Among various 3D bioprinting techniques, extrusion-based 3D bioprinting ensures a higher percentage of cell release, ensuring suitable external and internal scaffold architectures. Scaffold architecture is mainly defined by filament geometry and width.

View Article and Find Full Text PDF

Traditional tissue engineering strategies focus on geometrically static tissue scaffolds, lacking the dynamic capability found in native tissues. The emerging field of 4D bioprinting offers a promising method to address this challenge. However, the requirement for consistent exogenous supplementation of growth factors (GFs) during tissue maturation poses a significant obstacle for in vivo application of 4D bioprinted constructs.

View Article and Find Full Text PDF

Machine learning interatomic potentials (MLIPs) are used to estimate potential energy surfaces (PES) from calculations, providing near-quantum-level accuracy with reduced computational costs. However, the high cost of assembling high-fidelity databases hampers the application of MLIPs to systems that require high chemical accuracy. Utilizing an equivariant graph neural network, we present an MLIP framework that trains on multifidelity databases simultaneously.

View Article and Find Full Text PDF

Calcium sulfate-based load-bearing bone grafts with patient-specific geometry.

J Mech Behav Biomed Mater

February 2025

Department of Mechanical Engineering, University of Colorado, Boulder, CO, USA. Electronic address:

The treatment of bone defects with complex three-dimensional geometry presents challenges in terms of bone grafting and restoration. In this paper, we propose a rapid and effective method that uses 3D printing, ceramic casting, and the incorporation of mesh reinforcement to create load-bearing bone grafts with patient-specific three-dimensional geometry. Using two types of facial bones as examples, we show that this fabrication method has a high degree of geometrical fidelity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!