Statement Of Problem: Implant placement in the anterior regions is often challenging because of limited space and bone volume availability.
Purpose: The purpose of this clinical study was to investigate the accuracy of computer-guided surgery with a long drill key to place implants in the anterior regions.
Material And Methods: Computer-guided implant surgery was performed for 32 participants requiring implants in anterior regions. The procedure involved using a 12-mm-long drill key to guide the 2.0-mm-diameter drill. Deviations between the planned and actual implant positions were evaluated by using cone beam computed tomography (CBCT) scans obtained before and after surgery. A t test was used for comparisons between the planned and placed implants and to determine the influence of the arch (maxilla/mandible) and time (immediate/delayed) on accuracy.
Results: A total of 40 implants (20 implants in the maxilla and 20 implants in the mandible) were placed. The mean linear deviation was 0.46 mm (range, 0 to 1.15 mm) for the implant shoulder and 0.67 mm (range, 0.14 to 1.19 mm) for the implant apex. The mean angular deviation was 1.40 degrees (range, 0.30 to 2.57 degrees). The mean depth deviation was 0.15 mm (range, 0.10 to 0.82 mm).
Conclusions: This clinical study showed that the accuracy of computer-guided implant placement may be enhanced by using a long drill key and may thus enable more accurate implant placement in anterior regions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2018.07.015 | DOI Listing |
BMJ Open
January 2025
Shanghai Key Laboratory of Craniomaxillofacial Development and Diseases, Fudan University, Shanghai, China
Introduction: Soft-tissue defect is commonly seen in immediate maxillary posterior implantation because of tooth extraction wound and tension from bone graft. Bone graft materials exposure has a significant detrimental influence on bone augmentation. However, previous studies lack sufficient evidence to guide wound closure after immediate posterior implantation.
View Article and Find Full Text PDFJ Orthop Sci
January 2025
Department of Orthopedics, First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning 116011, China. Electronic address:
Purpose: A finite element analysis was performed to simulate the biomechanical differences between anterior-posterior (AP) direction and posterior-anterior (PA) direction placement of two cannulated screws in Hoffa fractures.
Methods: Computed tomography images of an healthy male volunteer were used to simulate Letenneur Ⅰ, Ⅱa, Ⅱb, Ⅱc, Ⅲ Hoffa fractures, and two groups of screw internal fixation models were constructed. Two 6.
Eur Arch Otorhinolaryngol
January 2025
Department of Radiology, Istanbul Training and Research Hospital, University of Health Sciences, Istanbul, Turkey.
Purpose: Cochlear implantation (CI) surgery is essential for restoring hearing in individuals with severe sensorineural hearing loss. Accurate placement of the electrode within the cochlea is essential for successful auditory outcomes and minimizing complications. This study aims to analyze the relationship between the round window niche (RWN) alignment, its visibility during surgery, and the impact on surgical techniques and outcomes.
View Article and Find Full Text PDFJ Prosthet Dent
January 2025
Assistant Professor, Restorative and Prosthodontic Department, The Ohio State University College of Dentistry, Columbus, OH.
Statement Of Problem: Although immediate implant loading has shown promising clinical results and high survival rates, an increased risk of implant failure and complications has been reported. Achieving consistently predictable outcomes with this approach remains a challenge, but evidence-based guidelines to assist in selecting suitable patients are lacking.
Purpose: The purpose of this retrospective clinical study was to investigate the success rate, survival rate, and complications of immediate implant loading compared with early and delayed loading.
J Neurosurg Pediatr
January 2025
Departments of1Neurosurgery and.
Objective: Intraventricular baclofen (IVB) administration is used for the treatment of secondary dystonia associated with cerebral palsy (CP), but it has not been reported as a first-line infusion technique for spasticity. In this study, the authors report outcomes of patients with mixed or isolated spasticity treated with IVB administration.
Methods: A retrospective analysis was performed of consecutive patients treated with IVB between 2019 and 2023.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!