Purpose: As computed tomography (CT) imaging is the most commonly used modality for treatment planning in radiation therapy, metal artifacts in the planning CT images may complicate the target delineation and reduce the dose calculation accuracy. Although current CT scanners do provide certain correction steps, it is a common understanding that there is not a universal solution yet to the metal artifact reduction (MAR) in general. Particularly noting the importance of MAR for radiation treatment planning, we propose a novel MAR method in this work that recruits an additional tilted CT scan and synthesizes nearly metal-artifact-free CT images.

Methods: The proposed method is based on the facts that the most pronounced metal artifacts in CT images show up along the x-ray beam direction traversing multiple metallic objects and that a tilted CT scan can provide complementary information free of such metal artifacts in the earlier scan. Although the tilted CT scan would contain its own metal artifacts in the images, the artifacts may manifest in a different fashion leaving a chance to concatenate the two CT images with the metal artifacts much suppressed. We developed an image processing technique that uses the structural similarity (SSIM) for suppressing the metal artifacts. On top of the additional scan, we proposed to use an existing MAR method for each scan if necessary to further suppress the metal artifacts.

Results: The proposed method was validated by a simulation study using the pelvic region of an XCAT numerical phantom and also by an experimental study using the head part of the Rando phantom. The proposed method was found to effectively reduce the metal artifacts. Quantitative analyses revealed that the proposed method reduced the mean absolute percentages of the error by up to 86% and 89% in the simulation and experimental studies, respectively.

Conclusions: It was confirmed that the proposed method, using complementary information acquired from an additional tilted CT scan, can provide nearly metal-artifact-free images for the treatment planning.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6333137PMC
http://dx.doi.org/10.1002/acm2.12523DOI Listing

Publication Analysis

Top Keywords

metal artifacts
28
proposed method
20
tilted scan
16
treatment planning
12
metal
9
method
8
radiation therapy
8
artifacts
8
mar method
8
additional tilted
8

Similar Publications

Convergent-Diffusion Denoising Model for multi-scenario CT Image Reconstruction.

Comput Med Imaging Graph

January 2025

The Department of Computer and Data Science, Case Western Reserve University, Cleveland, OH, USA; The Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.

A generic and versatile CT Image Reconstruction (CTIR) scheme can efficiently mitigate imaging noise resulting from inherent physical limitations, substantially bolstering the dependability of CT imaging diagnostics across a wider spectrum of patient cases. Current CTIR techniques often concentrate on distinct areas such as Low-Dose CT denoising (LDCTD), Sparse-View CT reconstruction (SVCTR), and Metal Artifact Reduction (MAR). Nevertheless, due to the intricate nature of multi-scenario CTIR, these techniques frequently narrow their focus to specific tasks, resulting in limited generalization capabilities for diverse scenarios.

View Article and Find Full Text PDF

Background: Early detection of peri-implant bone defects can improve long-term durability of dental implants. By the advances in cone-beam computed tomography (CBCT) scanners and introduction of new algorithms, it is important to find the most efficient protocol for detection of bone defects. This study aimed to assess the efficacy of metal artifact reduction (MAR) and advanced noise reduction (ANR) algorithms for detection of peri-implant bone defects.

View Article and Find Full Text PDF

Dual-energy CT in head and neck applications.

Neuroradiol J

January 2025

Division of Neurological Radiology, Department of Diagnostic and Therapeutic Radiology, Ramathibodi Hospital, Mahidol University, Thailand.

Dual-energy CT (DECT), also known as spectral CT, has advanced diagnostic capabilities in head and neck pathologies beyond those of conventional single-energy CT (SECT). By having images at two distinct energy levels, DECT generates virtual monoenergetic images (VMIs), iodine maps, and quantitative features such as iodine concentration (IC) and spectral Hounsfield unit attenuation curves (SHUAC), which leads to enhancing tissue characterization, reducing artifacts, and differentiating head and neck pathologies. This review highlights DECT's applications in evaluating head and neck squamous cell carcinoma (SCC), thyroid cartilage invasion, cervical lymph node metastasis, radiation therapy planning, post-treatment assessment, and role in other head and neck conditions, such as infection and sialolithiasis.

View Article and Find Full Text PDF

Evaluation of Pedicle Screw Position on Computerized Tomography Using Three-Dimensional Reconstruction Software.

Medicina (Kaunas)

December 2024

Spine Center and Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea.

: Recent advances in intraoperative navigation systems have improved the accuracy of pedicle screw placement in spine surgery. However, many hospitals have limited access to these advanced technologies due to resource constraints. In such settings, postoperative computed tomography (CT) evaluation remains crucial for assessing screw placement and related potential complications.

View Article and Find Full Text PDF

Extracellular nanoparticles (EPs) are a subject of increasing interest for their biological role as mediators in cell-cell communication; however, their harvesting and assessment from bodily fluids are challenging, as processing can significantly affect samples. With the aim of minimizing processing artifacts, we assessed the number density () and hydrodynamic diameter () of EPs directly in diluted plasma and blood using the following recently developed technique: interferometric light microscopy (ILM). We analyzed 613 blood and plasma samples from human patients with inflammatory bowel disease (IBD), collected in trisodium citrate and ethylenediaminetetraacetic acid (EDTA) anticoagulants, and 163 blood and plasma samples from canine patients with brachycephalic obstructive airway syndrome (BOAS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!