A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Infection Control Barrier and Curing Time as Factors Affecting the Irradiance of Light-Cure Units. | LitMetric

Infection Control Barrier and Curing Time as Factors Affecting the Irradiance of Light-Cure Units.

J Int Soc Prev Community Dent

Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.

Published: November 2018

Objective: The objective of the study is to investigate the effect of infection control barrier (ICB) and curing time on irradiance of light cure units (LCUs).

Methods: Irradiance (mW/cm) of the LCUs at a government dental school were recorded with and without ICB at 0 (T), 10 (T), and 20 (T) seconds using a digital radiometer. Data were analyzed using IBM SPSS Statistics Version 17 for Windows software for the analysis of variance and Bonferroni methods at 0.05 significance level.

Results: Using ICB resulted in a statistically significant effect on the irradiance mean ( < 0.01). A significant difference existed between the four different brands of LCUs at different time intervals, irrespective of the use of ICB. At T and T, the mean output of Acteon mini-light-emitting diode (LED) was significantly higher than that of either the Kerr Demi Ultra or the Kavo Polylux II. At T, E-Morlit's mean irradiance was significantly higher than that of Kerr Demi Ultra, which in turn was significantly higher than that of the Kavo PolyLux II. The mean irradiance of the LEDs was significantly higher than that of the halogens irrespective of barrier placement and at all-time points.

Conclusion: The ICB used in this study resulted in a statistically significant reduction in the irradiance output. No significant difference in the irradiance was found at different curing time intervals for the tested units regardless of ICB usage.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6280572PMC
http://dx.doi.org/10.4103/jispcd.JISPCD_226_18DOI Listing

Publication Analysis

Top Keywords

curing time
12
infection control
8
control barrier
8
irradiance
8
time intervals
8
higher kerr
8
kerr demi
8
demi ultra
8
kavo polylux
8
icb
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!