A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of historical negative control group data from the in vitro micronucleus assay using human lymphocytes. | LitMetric

A database of the micronuclei counts was built up for historical negative control data from human lymphocyte in vitro micronuclei tests (MnVit) carried out in 8 laboratories with experience of the method. The mean incidence of micronucleated cells (mnt)/1000 cells ranged from 2.2/1000 to 15.9/1000. There were no large differences in incidence between the presence or absence of S9 mix or between different treatment lengths. There was also little evidence that different solvents affected the numbers of micronuclei appreciably. A number of laboratories did show significant inter-experiment variability, indicating that there remained unidentified factors affecting frequencies. Donor variance may be one such factor. Inter-individual variability may explain some of these differences. The approximate 7.5-fold difference in mnt/1000 scores in a relatively small group of experienced laboratories illustrates the potential complications that can arise if a metric like a fold increase was considered the only biologically important finding. Although there is inherent variability between experiments, it was evident that within a laboratory the overall laboratory mean remains constant over time. It is believed that these findings will provide help to laboratories conducting studies using human lymphocytes in the MnVit and to those involved in the assessment of MnVit results.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mrgentox.2018.08.009DOI Listing

Publication Analysis

Top Keywords

historical negative
8
negative control
8
human lymphocytes
8
analysis historical
4
control group
4
group data
4
data vitro
4
vitro micronucleus
4
micronucleus assay
4
assay human
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!